12
1143923-W2-E
6. Reversed Inlet Supplies Only:
a)
Remove the sealing plug using the 'O' key
(supplied).
b)
Unscrew the outlet nipple using the
‘O’ key (supplied) or a 12 mm hexagonal
key.
c)
Refit the sealing plug and outlet nipple in
the opposite outlets and tighten.
Note!
Make sure that the ‘O’ seals are
correctly fitted.
d)
Rotate the mixer 180°.
e)
The control lever(s) will have to be
realigned, this can be completed in
section:
‘Commissioning’
.
7.
Remove the backplate from the mixer by
loosening the grubscrews with a 2.5 mm
hexagonal key (supplied).
8.
Secure the backplate to the wall using the
screws (supplied).
9. For Rear Entry Supplies Only:
a)
Fit the concealing plates over the inlet
pipes.
Note!
Apply silicone sealant to the back
face of the flange.
10. Caution! It is essential at this point
that the supply pipework is thoroughly
flushed through before connection to the
mixer.
Failure to do so may result in product
malfunction and will not be covered under the
guarantee.
11.
Fit the compression nuts and olives onto the
pipework.
12.
Align the mixer with the pipework and fit onto
the backplate.
Important!
Make sure that the hot and cold
inlets on the mixer correspond with the hot and
cold inlet supplies.
13.
Tighten the compression nuts onto the mixer
with a suitable spanner.
Caution!
Take care not to damage the chrome
surfaces.
14.
Tighten the grubscrews to secure the mixer to
the backplate.
15.
Fit the shower fittings, refer to your shower
fittings installation and user guide for
instructions.
Important!
For high pressure systems (above
0.5 bar) make sure that the flow regulator
(supplied) is fitted, refer to section:
‘Flow
Regulators’
.
16.
Turn on the hot and cold water supplies and
check for leaks.
17.
Before using the shower, refer to section:
‘Commissioning’
.
Sealing Plug
‘O’ Seal
Screw
Backplate
Olive
Compression Nut
Apply Silicone Sealant
Concealing Plate