SPECIFICATION
General
Protection
IP20
Connections
1 1/2 BSP Internal (female)
Installation Environment
Suitable for indoor use only
Pressures
Maximum Static Pressure
1000 kPa (10 bar)
Maximum Operating Pressure Drop
across DRV
140 kPa (1.4 bar)
Supply Pressure Differential
Equal pressure recommended - Inlet pressures
must
be stable for optimum
performance.
Temperatures
Cold Water Range
2 - 25°C
Hot Water Range
2°C above setpoint - 80°C
Optimum Setpoint Range
27 - 70°C
Ambient Temperature
Greater than 2°C, max. 50°C
Maximum Relative Humidity
95% non-condensing
Recirculation Circuit
Minimum distance to First Outlet
7.6 m
Flow Rates
Minimum Flow Rate Per Outlet
6 l/min (<500kPa maintained pressure)
8 l/min (>500kPa maintained pressure)
Maximum recommended Flow Rate
155 l/min at 2.3 m/s
Minimum recirculation Flow Rate
19 l/min
Minimum system Draw-off
0 l/min during recirculation
2 l/min from 1 outlet
Electrical
Power Supply
230V ~ 50Hz 15W
Supply Fuse
Switched type 3 Amp
Internal Fuse (Electronics Module)
T2AH 250V
Battery
2 x CR - P2 6V
Duty cycle
Continuously rated
Auxiliary Relay
(see Alerts - Activate Relay on Alert)
Relay Type
Single pole changeover relay contacts
Power Supply
230V AC / 24V DC
Supply Fuse
2 Amp
The Rada DRV40 conforms to the CE marking requirements.
Summary of Contents for DRV40
Page 43: ...43 Step 5 Step 6 ...
Page 47: ...47 3mm HEX Step 5 3mm HEX Step 6 ...
Page 48: ...48 3mm HEX Step 7 Step 7a Step 7b Seals shown 1 1 when printed at Full Scale ...
Page 51: ...51 A D B E C x 2 x 3 Seals shown 1 1 when printed at Full Scale ...
Page 70: ...70 NOTES ...
Page 71: ...71 NOTES ...