58
Common Faults
Problem:
“Blend temperature rises when system is in zero demand...”
DRV40 display errors
These are the most likely error
messages to be displayed
during this problem. For the
most probable causes and
solutions see
'DRV40 Display
Errors'
.
If any other error message is displayed see
'DRV40 Display Errors'
.
Error PCB
Temp 49˚C
Error Motor
Temp 49˚C
Error Thermistor
Temp 49˚C
Temp High
Error Temp
49˚C
Summary of Contents for DRV40
Page 43: ...43 Step 5 Step 6 ...
Page 47: ...47 3mm HEX Step 5 3mm HEX Step 6 ...
Page 48: ...48 3mm HEX Step 7 Step 7a Step 7b Seals shown 1 1 when printed at Full Scale ...
Page 51: ...51 A D B E C x 2 x 3 Seals shown 1 1 when printed at Full Scale ...
Page 70: ...70 NOTES ...
Page 71: ...71 NOTES ...