14
5.
Connect and secure the 4 and 8 pin
plugs to the back of the Electronics
Module.
6.
Connect the Power Cable to the
mains electricity.
A separate, permanently connected
supply
must
be taken from the ring
main to the appliance through a
3 Amp double pole switched fuse
spur providing a minimum 3mm
contact separation gap in each
pole. The fuse spur must be suitably
located, easily reached and identified
as to its purpose.
7.
Close and secure the Electronics
Module with the 2 x 4mm hexagon
socket screws provided.
Note! The Electronics Module
must be closed for the DRV40 to
function.
8.
C o m m i s s i o n t h e D R V 4 0 a n d
recirculation system using the
'Commissioning'
instructions
contained in this manual.
Power Cable
4mm
HEX