59
Stop Valve
Full Bore Isolating Valve
Pressure Reducing Valve
Shower
Thermometer
Cold Water
Hot Water
Mixed Water
Check Valve
Recirculation Pump
Key
Strainer / Filter
Needle Valve
Flow indicator
Safety Valve
Water
Heater
Check blend circuit flow rate.
Flow rate is less than 19 l/m. Reset circuit
flow rate and check for the following:
•
Air locks
•
Blocked strainers
•
Closed valves
•
Pump failure
Water pressure
Make sure supply pressures are balanced.
Make sure mixed return is flowing correctly
to hot water supply inlet.
Checkvalves
Check circuit to make sure checkvalves are
correct positioned and operating normally.
(See
Recirculation Circuit - Plumbing
Schematic
)
Check mixed return temperature.
Minimum recirculation loop temperature
loss = 1°C