User Manual 1260-30
Installation Instructions 2-2
Option 01
Installation
Installation of the Option 01 into the 1260-30 is described in the
Installation section of the 1260 Series VXI Switching Cards
Manual.
Module
Installation
Installation of the 1260-30 Switching Module into a VXI mainframe,
including the setting of DIP switches, is described in the
Installation section of the 1260 Series VXI Switching Cards
Manual. Configuration of the PCBA and setting DIP switches
SW1-5 and SW1-6 are described in the following sections.
Configuration
Settings
The 1260-30 is configurable as 1x40, two 1x20, four 1x10, or eight
1x5 multiplexers. The configuration is set by the installation of 24
gage jumpers to the board as follows:
Model
1260-30A
1260-30B
1260-30C
1260-30D
Configuration
One 1X40
Two 1X20
Four 1X10
Eight 1X5
Jumpers
All
J1, J2, J3, J5, J6. and J7
J1, J3, J5, and J7
None
Note this illustrates the principle of the 1260-30 configuration
setting. The connections to be made on the PCB are given on the
following pages.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com