![background image](http://html1.mh-extra.com/html/racal-instruments/1260-100/1260-100_manual_3135459041.webp)
1260-100/101 Adapt-a-Switch Carrier Module User Manual
A-4
Power Available
+5V: 4.5A
(per plug-in)
+12V: 0.75A
+24V: 0.75A
Cooling (worst-case
Airflow:
1.5 liters/sec
plug-in configuration)
Backpressure:
0.7 mm H
2
0
Environmental
Temperature
Operating:
0
°
C to +55
°
C
Non-operating:
-40
°
C to +70
°
C
Relative Humidity
95% RH non-condensing
Altitude
Operating:
10,000 ft.
Non-operating:
15,000 ft.
Vibration
0.013 in. P-P, 5 Hz to 55 Hz; meets
MIL-T-28800C Type III, Class 5,
Style F
Shock
30g, 11 ms, 1/2 sine wave
Bench Handling
4 inch drop at 45
°
EMC and Safety
Emissions
EN61326: 1997+A1:1998, Class A
Susceptibility, Safety
EN61010-1:1993+A2:1995
Reliability
Mean Time Between
>
315,749 hours, MIL-HBK-217,
Failures (MTBF)
ground-benign, 30
o
C
Mean Time To Repair
Replace plug-in: 5 min.
(MTTR)
Replace other:
<30 min.
*Measured from start of VXIbus cycle until relay coil is fully energized.