background image

Choosing a Location

The best location is where the sensor can “see” all paths
of movement.  The sensor may be wall or soffit mounted.

As distance from the sensor increases, larger movement
will be required for detection. For instance, at 10 feet, a
half step will be enough, while at 50 feet several steps will
be necessary for detection.

How large an area does STL360 protect?

Two powerful detectors combine to give the STL360 180°
x 60’ long forward range plus superb 360° downward
detection below and to all sides. 

Mounting Height 

Mounting at 6-12’ above the ground allows maximum
range.  If the sensor is mounted above 15’ high, the
usable range is reduced. 

Location Tips

Difficult Locations

Sensor may be triggered by 
unwanted movement or heat source,
such as a swaying tree, road traffic, 
dryer vent, swimming pool or hot tub.

To Improve Performance in Difficult Locations: 

•  Reduce sensitivity by

turning the SENS knob
counterclockwise, 

and/or…

•  Mask lens in the direction 

of the unwanted movement 
or heat source using the lens 
mask provided or opaque tape

Mounting Stability

• Mount sensor on stable surface. 

Do not mount on a tree or pole 
that will move in the wind. 

•  Make sure sensor and lights are 

mounted firmly.  If they move when
touched, tighten all screws.

Light vs. Sensor Position

•  Make sure heat from lights is not 

triggering sensor. Sensor must be
located below and as far away 
as possible from its lights. 

STL360Q1, STL360Q2 & STL360Q3 Kits

Mount only on non-combustible surfaces. 

Side View

6-10'

wrong

wrong

OK!

TIME

1           8 HRS

5 SECS          12 MINS

–         +

EVENING
  TIMER

SENS

20’

40’

6-10’

60’

Reduced Range

Maximum Range

mask

4

3

60’

60’

20’

Summary of Contents for STL360H

Page 1: ...rol Systems such as X 10 Leviton or Radio Shack are incompatible with sensors and may cause false activations Do not install sensors on a circuit that feeds motor loads such as kitchen appliances HVAC equipment washer dryer or garage door openers Sensor functions best when the direction of expected movement is across its detection pattern not towards the sensor Mount 6 12 high for optimum range an...

Page 2: ... vacated lights can be adjusted to remain on from approximately 5 seconds up to 12 minutes Since the lights are on only when needed and the sensor uses only one watt the STL360 is extremely energy efficient Can lights still be turned on with the light switch Yes STL360 can be controlled by a conventional indoor switch or circuit breaker The STL360 operates in Auto Mode unless changed The light can...

Page 3: ...ered by unwanted movement or heat source such as a swaying tree road traffic dryer vent swimming pool or hot tub To Improve Performance in Difficult Locations Reduce sensitivity by turning the SENS knob counterclockwise and or Mask lens in the direction of the unwanted movement or heat source using the lens mask provided or opaque tape Mounting Stability Mount sensor on stable surface Do not mount...

Page 4: ... high in the air over people s heads Choosing a Location Locate for Movement Across Pattern Check that movement is not directly towards sensor Sensor will see movement ACROSS its pattern more quickly Check that movement far away and directly towards sensor is not entirely within one zone To fix change the sensor location If the sensor is located over a pathway so all movement is directly toward it...

Page 5: ...ing screw Connect as shown in wiring diagram on page 7 6 Twist on wire nuts Secure with electrical tape 7 Align gaskets EZ Plate and metal mounting plate to insure proper seal Tighten EZ Plate center screw make sure O Ring gasket is on the screw to attach EZ Plate to the box 8 Insert plastic Finishing Cap in the center of the CU4 EZ Plate for a weatherproof seal 9 Use silicone sealant around all o...

Page 6: ...g 7 8 Strip 1 2 of insulation from all leads Connect as shown in wiring diagram 9 Twist on wire nuts Secure with electrical tape 10 Make sure all unused openings in EZ Plate are closed with plugs provided 11 Screw in light bulbs Turn on power 12 Conduct Walk Test to adjust sensor response see page 15 STL360 Assembly and Wiring Multiple Sensors Multiple sensors may be wired together but doing this ...

Page 7: ...TIMER provides a lived in look by simulating an occupant turning lights on at dusk and then off at bedtime To set the EVENING TIMER flip the wall switch controlling the sensor three times slowly off on off on off on within 3 seconds If you set the EVENING TIMER during daytime the middle LED should start blinking indicating that the Evening Timer will start when dusk is detected Choose the length o...

Page 8: ...Ds will appear when test mode ends If you require 2 more minutes of Test Mode turn the power off for at least 10 seconds and back on again In Test Mode no LEDs are lit MANUAL OVERRIDE MODE The STL360 has a protected Manual Override that requires a double flip of the light switch so momentary power problems do not interfere with normal sensor operation By flipping the switch that operates the senso...

Page 9: ... not in Manual Override Mode Turn power OFF for 10 seconds then ON Sensor will be in Test Mode for approximately 2 minutes then it will switch to Auto Mode with lights off and ready to detect movement 2 Make sure that the sensor is not in Evening Timer Mode Turn power OFF for 10 seconds see 1 3 Make sure sensor is not aimed at or mounted over something that would move or change temperature such as...

Page 10: ...e attracted to the lights and fly close to the sensor causing triggering Reducing the sensitivity may help 9 Check Solutions 3 4 5 6 7 and 8 under If Lights Do Not Turn Off Technical Tips Lights Turn On and Off Inappropriately 1 Check that lamps and fixtures work Compare wiring to the wiring diagram in this manual Check that the power is on 2 If installing during daylight remember that the sensor ...

Page 11: ...ider using lower wattage energy saving lamps TIME 12 MINS SENS OK WRONG 1 Check that the sensor is level from side to side and pointed at the area you desire If unit is tilted part of the detection zone may be high in the air over people s heads Solution Position sensor exactly level from side to side 2 Check that the sensor is not mount ed too high If mounted above 20 feet much of the usable rang...

Page 12: ...ric We will repair or replace your unit Under no circumstances shall we be liable for any incidental or consequential damages arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property or revenue or cost of installation removal or re installation This warranty gives you specific legal rights and you may also have other rig...

Reviews: