background image

STL360 Assembly and Wiring

■ 

To install a STL360 Sensor with separately 

purchased floodlights, start at #1.

■ 

To install STL360 Pre-wired Floodlight Kits, 

see page 7.

1. Screw the threaded arms of each floodlight into the 

RAB CU4 EZ Plate. ( See diagram on page 7)

2. Screw the threaded arm of the sensor into the bottom

hole of the EZ Plate.  Sensor should be below and as far
away from the floodlights as possible.

3. Attach the Universal Mounting bar with the bar screws 

(provided) to the junction box. If you are attaching your
STL360 kit to a surface mount weatherproof box, you
must use both gaskets, with the metal mounting plate
sandwiched between. 

4. 

Easy Wiring Tip: 

Use the “S” shaped Hands Free Hanging Hook to hold
the EZ Plate during wiring. 

5. Bring power leads, light fixture and sensor leads through

holes in all gaskets and mounting plates into junction box.

6. Attach ground wire(s) to junction box grounding screw.

7. Position EZ Plate gaskets and metal plate. (see pg #7)

8. Strip 

1

/

2

" of insulation from all leads. Connect as shown

in wiring diagram.

9. Twist on wire nuts.

Secure with

electrical tape.

10. Make sure all unused

openings in EZ Plate are
closed with plugs (provided).

11. Screw in light bulbs. Turn on power.

12. Conduct Walk Test to adjust sensor response (see

page 15).

STL360 Assembly and Wiring

Multiple Sensors

Multiple sensors may be wired together, but doing this will
make problems difficult to troubleshoot.  Single sensors
that control their own lights will give a more accurate
location of movement and trouble-free operation.

Multiple Fixtures

Multiple fixtures may be 

wired to a single sensor.

To handle loads greater 

than 1,000 watts, 

a qualified electrician 

should install

a relay.

Power

Quality

It is not recommended to install sensors on a circuit that
also feeds motor loads such as HVAC equipment, kitchen
appliances, or garage door openers. The Stealth circuit is
surge and transient protected to IEC specifications.
However, if voltage varies significantly from 120 volts,
which may occur on circuits with motor loads, the sensor
may malfunction. 

10

Power In

White

Red

Black

Power In

White

Sensor

Red

Black

9

Black

Summary of Contents for STL360H

Page 1: ...rol Systems such as X 10 Leviton or Radio Shack are incompatible with sensors and may cause false activations Do not install sensors on a circuit that feeds motor loads such as kitchen appliances HVAC equipment washer dryer or garage door openers Sensor functions best when the direction of expected movement is across its detection pattern not towards the sensor Mount 6 12 high for optimum range an...

Page 2: ... vacated lights can be adjusted to remain on from approximately 5 seconds up to 12 minutes Since the lights are on only when needed and the sensor uses only one watt the STL360 is extremely energy efficient Can lights still be turned on with the light switch Yes STL360 can be controlled by a conventional indoor switch or circuit breaker The STL360 operates in Auto Mode unless changed The light can...

Page 3: ...ered by unwanted movement or heat source such as a swaying tree road traffic dryer vent swimming pool or hot tub To Improve Performance in Difficult Locations Reduce sensitivity by turning the SENS knob counterclockwise and or Mask lens in the direction of the unwanted movement or heat source using the lens mask provided or opaque tape Mounting Stability Mount sensor on stable surface Do not mount...

Page 4: ... high in the air over people s heads Choosing a Location Locate for Movement Across Pattern Check that movement is not directly towards sensor Sensor will see movement ACROSS its pattern more quickly Check that movement far away and directly towards sensor is not entirely within one zone To fix change the sensor location If the sensor is located over a pathway so all movement is directly toward it...

Page 5: ...ing screw Connect as shown in wiring diagram on page 7 6 Twist on wire nuts Secure with electrical tape 7 Align gaskets EZ Plate and metal mounting plate to insure proper seal Tighten EZ Plate center screw make sure O Ring gasket is on the screw to attach EZ Plate to the box 8 Insert plastic Finishing Cap in the center of the CU4 EZ Plate for a weatherproof seal 9 Use silicone sealant around all o...

Page 6: ...g 7 8 Strip 1 2 of insulation from all leads Connect as shown in wiring diagram 9 Twist on wire nuts Secure with electrical tape 10 Make sure all unused openings in EZ Plate are closed with plugs provided 11 Screw in light bulbs Turn on power 12 Conduct Walk Test to adjust sensor response see page 15 STL360 Assembly and Wiring Multiple Sensors Multiple sensors may be wired together but doing this ...

Page 7: ...TIMER provides a lived in look by simulating an occupant turning lights on at dusk and then off at bedtime To set the EVENING TIMER flip the wall switch controlling the sensor three times slowly off on off on off on within 3 seconds If you set the EVENING TIMER during daytime the middle LED should start blinking indicating that the Evening Timer will start when dusk is detected Choose the length o...

Page 8: ...Ds will appear when test mode ends If you require 2 more minutes of Test Mode turn the power off for at least 10 seconds and back on again In Test Mode no LEDs are lit MANUAL OVERRIDE MODE The STL360 has a protected Manual Override that requires a double flip of the light switch so momentary power problems do not interfere with normal sensor operation By flipping the switch that operates the senso...

Page 9: ... not in Manual Override Mode Turn power OFF for 10 seconds then ON Sensor will be in Test Mode for approximately 2 minutes then it will switch to Auto Mode with lights off and ready to detect movement 2 Make sure that the sensor is not in Evening Timer Mode Turn power OFF for 10 seconds see 1 3 Make sure sensor is not aimed at or mounted over something that would move or change temperature such as...

Page 10: ...e attracted to the lights and fly close to the sensor causing triggering Reducing the sensitivity may help 9 Check Solutions 3 4 5 6 7 and 8 under If Lights Do Not Turn Off Technical Tips Lights Turn On and Off Inappropriately 1 Check that lamps and fixtures work Compare wiring to the wiring diagram in this manual Check that the power is on 2 If installing during daylight remember that the sensor ...

Page 11: ...ider using lower wattage energy saving lamps TIME 12 MINS SENS OK WRONG 1 Check that the sensor is level from side to side and pointed at the area you desire If unit is tilted part of the detection zone may be high in the air over people s heads Solution Position sensor exactly level from side to side 2 Check that the sensor is not mount ed too high If mounted above 20 feet much of the usable rang...

Page 12: ...ric We will repair or replace your unit Under no circumstances shall we be liable for any incidental or consequential damages arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property or revenue or cost of installation removal or re installation This warranty gives you specific legal rights and you may also have other rig...

Reviews: