background image

Walk Testing

STL360’s full coverage pattern reduces the need for aiming
and adjustment.  The purpose of the Walk Test is to check
and adjust the coverage pattern. The STL360 has a Test
Period which allows the sensor to be walk tested day or
night. 

To enter Test Mode:
The sensor is in Test Mode when power is first applied.
Turn power off for at least 10 seconds and back on.

1. Aim the sensor at the traffic pattern you want to detect.

Sensor will detect any  movement ACROSS its pattern
most effectively.

2. Start outside the pattern

and walk across the pattern
until the lights go on. As
distance from the sensor
increases, it will take more
movement to be detected.

3. Adjust sensor aiming as necessary to improve coverage.

Make sure sensor is level.

4. Sensitivity may be decreased with the SENS knob to

detect a limited area or if the sensor is being activated by
wind, foliage, traffic or animals, or increased to cover a
larger area. [See p. 11-12 to adjust sensor settings.]  The
lens mask can also be used to drastically reduce coverage,
or allow undetected movement from some directions.

5. STL360 is factory set for night only operation. For 24

hour operation, turn the photocell control completely
toward the SUN/MOON setting. Turn counter clockwise 
to have the sensor come on later at dusk, clockwise to
have it come on earlier.

6. Repeat steps 1-5  until you are satisfied with coverage.

Your sensor is now ready for operation.

Technical Tips:
Lights Do Not Turn Off

1. Make sure that the sensor is not in Manual Override Mode. Turn power
OFF for 10 seconds, then ON Sensor will be in Test Mode for approximately
2 minutes, then it will switch to Auto Mode with lights off and ready to
detect movement.

2. Make sure that the sensor is not in Evening Timer Mode.  Turn power
OFF for 10 seconds (see #1).

3. Make sure sensor is not aimed at or mounted over something that would
move or change temperature such as waving branches, water, air condi-
tioners, windows or heating vents—even on neighboring property. You can
test for infrared sources in the area by placing a box or bag over the sensor.
Put sensor into test mode. Lights should stay off. Wave your hand inside
bag in front of sensor. Lights should go on and then time out. If sensor
operates properly when covered, check items #4–8. 

Problem: Sensor is triggered by unwanted
movement or heat source.
Solution:  

(1) Aim sensor away from movement, or 
(2) Mask lens as in the direction of the source 
(3) Lower sensitivity control setting

4. Make sure sensor and lights are mounted firmly

and do not move even slightly when touched. If 

they move, tighten all screws. 

5. Make sure sensor is not mounted on an unstable object

such as a tree or pole that will move in the wind. 

Problem:  Movement of tree triggers sensor.
Solution:  Mount on stable surface.

6. Was sensor wired hot? If so, circuitry may have been damaged.

7. Make sure sensor is not aimed within 20   

feet of a road.

Problem:  Passing cars activate sensor.
Solution:  A 20 foot safety zone and lower  
sensitivity are  recommended to avoid activation
from passing cars.

8. Make sure heat from lights is not triggering 

sensor. Make sure the sensor is below and as 
far as possible away from  sensor.

16

20' 

safety 

zone 

OK!

15

Summary of Contents for STL360H

Page 1: ...rol Systems such as X 10 Leviton or Radio Shack are incompatible with sensors and may cause false activations Do not install sensors on a circuit that feeds motor loads such as kitchen appliances HVAC equipment washer dryer or garage door openers Sensor functions best when the direction of expected movement is across its detection pattern not towards the sensor Mount 6 12 high for optimum range an...

Page 2: ... vacated lights can be adjusted to remain on from approximately 5 seconds up to 12 minutes Since the lights are on only when needed and the sensor uses only one watt the STL360 is extremely energy efficient Can lights still be turned on with the light switch Yes STL360 can be controlled by a conventional indoor switch or circuit breaker The STL360 operates in Auto Mode unless changed The light can...

Page 3: ...ered by unwanted movement or heat source such as a swaying tree road traffic dryer vent swimming pool or hot tub To Improve Performance in Difficult Locations Reduce sensitivity by turning the SENS knob counterclockwise and or Mask lens in the direction of the unwanted movement or heat source using the lens mask provided or opaque tape Mounting Stability Mount sensor on stable surface Do not mount...

Page 4: ... high in the air over people s heads Choosing a Location Locate for Movement Across Pattern Check that movement is not directly towards sensor Sensor will see movement ACROSS its pattern more quickly Check that movement far away and directly towards sensor is not entirely within one zone To fix change the sensor location If the sensor is located over a pathway so all movement is directly toward it...

Page 5: ...ing screw Connect as shown in wiring diagram on page 7 6 Twist on wire nuts Secure with electrical tape 7 Align gaskets EZ Plate and metal mounting plate to insure proper seal Tighten EZ Plate center screw make sure O Ring gasket is on the screw to attach EZ Plate to the box 8 Insert plastic Finishing Cap in the center of the CU4 EZ Plate for a weatherproof seal 9 Use silicone sealant around all o...

Page 6: ...g 7 8 Strip 1 2 of insulation from all leads Connect as shown in wiring diagram 9 Twist on wire nuts Secure with electrical tape 10 Make sure all unused openings in EZ Plate are closed with plugs provided 11 Screw in light bulbs Turn on power 12 Conduct Walk Test to adjust sensor response see page 15 STL360 Assembly and Wiring Multiple Sensors Multiple sensors may be wired together but doing this ...

Page 7: ...TIMER provides a lived in look by simulating an occupant turning lights on at dusk and then off at bedtime To set the EVENING TIMER flip the wall switch controlling the sensor three times slowly off on off on off on within 3 seconds If you set the EVENING TIMER during daytime the middle LED should start blinking indicating that the Evening Timer will start when dusk is detected Choose the length o...

Page 8: ...Ds will appear when test mode ends If you require 2 more minutes of Test Mode turn the power off for at least 10 seconds and back on again In Test Mode no LEDs are lit MANUAL OVERRIDE MODE The STL360 has a protected Manual Override that requires a double flip of the light switch so momentary power problems do not interfere with normal sensor operation By flipping the switch that operates the senso...

Page 9: ... not in Manual Override Mode Turn power OFF for 10 seconds then ON Sensor will be in Test Mode for approximately 2 minutes then it will switch to Auto Mode with lights off and ready to detect movement 2 Make sure that the sensor is not in Evening Timer Mode Turn power OFF for 10 seconds see 1 3 Make sure sensor is not aimed at or mounted over something that would move or change temperature such as...

Page 10: ...e attracted to the lights and fly close to the sensor causing triggering Reducing the sensitivity may help 9 Check Solutions 3 4 5 6 7 and 8 under If Lights Do Not Turn Off Technical Tips Lights Turn On and Off Inappropriately 1 Check that lamps and fixtures work Compare wiring to the wiring diagram in this manual Check that the power is on 2 If installing during daylight remember that the sensor ...

Page 11: ...ider using lower wattage energy saving lamps TIME 12 MINS SENS OK WRONG 1 Check that the sensor is level from side to side and pointed at the area you desire If unit is tilted part of the detection zone may be high in the air over people s heads Solution Position sensor exactly level from side to side 2 Check that the sensor is not mount ed too high If mounted above 20 feet much of the usable rang...

Page 12: ...ric We will repair or replace your unit Under no circumstances shall we be liable for any incidental or consequential damages arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property or revenue or cost of installation removal or re installation This warranty gives you specific legal rights and you may also have other rig...