25 / 30
User Manual
Rev. 1.2 - 21/01/11
TEX2000LCD
Parameters
Conditions
U.M.
Value
Notes
AC Supply Voltage
VAC
230 ±15%
(*) Full range (**) Internal switch
AC Apparent Power Consumption
VA
2620
Active Power Consumption
W
2600
Power Factor
0,99
Connector
morsettiera
DC Supply Voltage
VDC
DC Current
ADC
(*)max 25W (**) max 140W
FUSES
On Mains
A
16 T - 10 x 38 mm
N° 2 External fuse
On PA Supply
A
N° 4 Internal fuses 16 F - 10 x 38 mm
On Driver Supply
A
Not Present
N° 1 Internal fuse
Front panel width
mm
483 (19")
19" EIA rack
Front panel height
mm
132 3HE
convertire in pollici
Overall depth
mm
675
compresi i connettori , compreso il pannello, escluse le
maniglie, convertire in pollici
Chassis depth
mm
650
escluso il pannello, esclusi i connettori, convertire in pollici
Weigh
kg
about 31
Analogical level
FWD fold
For P.A. A.G.C. purpose, min 0,5 Vcc
Analogical level
REF fold
For P.A. A.G.C. purpose, min 0,5 Vcc
pulse
RF ON
pulse
RF OFF
ON/OFF level
Interlock
for remote power inhibition (short is RF off)
Analogical level
FWD
max 5 Vcc
Analogical level
REF
max 5 Vcc
Analogical level
VPA
max 5 Vcc
Analogical level
IPA
max 5 Vcc
ON / OFF level
Power Good
open collector
Remote connector others
I2Cbus
TELEMETRY-TELECONTROL SW
Telecon
Yes, if /TLM option is present
Yes, via TLC300 or TLC2000 if /TLM
option is not present
VARIOUS
Cooling
Forced, with internal fan
Acoustic Noise
dBA
<75
STANDARD COMPLIANCE
Safety
EN 60215:1989 + EN60215/A1:1992-
07 + EN60215/A2:1994-09
EMC
EN 301 489-1 V1.4.1 (2002-08) + EN
301 489-11 V1.2.1 (2002-11)
Spectrum Optimization
EN 302 018-2 V1.2.1 (2005-06)
TELEMETRY / TELECONTROL
Phisical Dimensions
MECHANICAL DIMENSIONS
POWER REQUIREMENTS
DC Power Input
Remote connector inputs
Remote connector outputs
AC Power Input