11 / 30
User Manual
Rev. 1.2 - 21/01/11
TEX2000LCD
5.3 Operation
1) Power on the exciter and ensure that the ON light turns on. Equipment name
should appear briefly on the display, quickly followed by modulation and
forward power readings (Menu 1), provided that the exciter is delivering output
power.
Menu 1
1b) To modify power level setting, hold down the ENTER button until opening
the power setup menu.
The edit screen will look like this:
Menu 2
Next to SET indication, a bar provides a graphic display of preset output power.
The filled portion of the bar is proportional to set power level.
Example
100% output power
Full bar
≅
2kW output
50% output power
Half-full bar
≅
1000W output
25% output power
Quarter-full bar
≅
500W output
The bottom line provides instantaneous power reading (in this example 1.97kW,
falling below 1.6kW the reading back to Watt. As result of hysteresis power up ,
exceeding1400W the reading back to kWatt); press button
to increase level,
press
to decrease it. When you have achieved the desired level, press ENTER
to confirm and exit the
default menu. Please note that the setting is stored
automatically; in other words, if you press ESC or do not press any keys before
the preset time times out, the latest power level set will be retained.
NOTE: This feature prevents the equipment from delivering maximum power
as soon as output is enabled from menu 4, or in the event the equipment is
already set to ON when you energise it.