14 / 30
User Manual
Rev. 1.2 - 21/01/11
TEX2000LCD
As soon as operating conditions are restored, power output is re-enabled with the
same settings in use prior to the alarm condition.
Under 20kHz, no modulation occurs. After a preset time of about 5 minutes (not
editable), a NO AUDIO condition is indicated in the main screen, but power is not
inhibited.
State 2
To gain access to a submenu, select menu name (name is highlighted by cursor)
using button
or
and press the ENTER button.
To return to the default menu (menu 1), simply press ESC again.
5.4.1 Operation Menu (Fnc)
In this menu, you can toggle exciter power output On/Off, set deviation display
mode and the threshold rate for Forward (PgD) or
Reflected
(PgR) Power
Good.
To operate on one of this voices, select the relative line by the
and
buttons,
then press and keep pressed the ENTER button until the command doesn’t come
accepted. In this way the Pwr setting will become from On to Off, or viceversa, and
the Mod setting from “x1” to “x10” or viceversa. To modify the Power Good value
percentage is sufficient, after to have selected the “PgD” or “PgR” voice, set up
the value through the
and
buttons, then confirm with
ENTER.
Menu 4
Pwr
Enables (ON) or disables (OFF) exciter power output.
Mod
Modifies modulation display (toggles between “x1” and “x10”). In “x10”
mode, instantaneous deviation indication is multiplied by a factor of 10,
and the bar meter on the default menu will reflect 7.5 kHz instead of