2. Technical Specifications
/RDS-TFT2HE, /RDS-TFT3HE & /RDS-TFT4HE
Parameters
U.M.
Value
Standards
Cenelec 50067 Specification
Frequency
kHz
57 +/- 0,3Hz (internal reference)
Bandwidth
kHz
+/- 2,4 (-50dB)
Level
mVpp
2.200
Phase / Pilote
Deg.
Adjustable from 0 to 360 in 0.33 increments
Connector
IDC 10p Mas.
Impedance
ohm
50
Sync frequency
kHz
19 +/- 2Hz
Input level
dBu
from –30 to +4 (sinusoidal or TTL)
Connector
IDC 10p Mas.
Speed in continuous flow
bps
from 1200 to 19200
Programming speed
bps
from 1200 to 115200
Transmission format
8 bit – no parity – 1 stop bit
Connector
IDC 10p Mas.
Speed in continuous flow
bps
19200
Programming speed
bps
19200
Transmission format
8 bit – no parity – 1 stop bit
Connector
IDC 10p Mas.
D/A conversion
24 bit (Dynamic range 106 dB)
DSP
32 bit, fixed point
Ambient working temperature
°C
0 to + 50
Ambient Working Humidity
%
85 (Without condensing)
Services
PTY, PTYN, TA, TP, MS, DI, PI, PS, AF, PIN, EON, RT, TDC, TMC, EWS, IH, CT
DSN
6
PSN
N ° 1 PSN Main + N ° 7 PSN - EON for each DSN
PS (custom)
N 8 of 16 words managed in time and in mode
sliding or block
AF
N ° 100 Lists of 25 frequencies for each main PSN
RT
N° 16 for each DSN
EON
N° 100 AF
IH,TDC,TMC
N° 1 Buffer UECP, N° 1 Buffer FFG, N° 1 Buffer ODA (MEC42 , MEC45)
EWS
N° 1 Buffer UECP, N° 1 Buffer FFG
Groups
Custom management
Addresses
N ° 5 site addresses, 5 encoder addresses
Command formats
UECP - SPB490 Ver.6.1 / 2003
Custom functions
PS and DSN messages management
DC Supply Voltage
V
5
DC Current
A
0,2
Width
mm
74
Depth
mm
96
Weight
g
200
Safety
EN60215:1997
EMC
EN 301 489-11 V1.4.1
Elaboration
GENERAL
RDS Output
PILOTE input
Primary Serial Port
Auxiliary Serial Port
MECHANICAL DIMENSIONS
Phisical Dimensions
OTHER CONNECTORS
STANDARD COMPLIANCE
RDS SERVICES
Programs
Specifications
Programming
POWER REQUIREMENT
DC Power Input