/RDS-TFT2HE, /RDS-TFT3HE & /RDS-TFT4HE
ELETTRONICA
31
/ 34
User Manual
Rev. 1.0 - 01/02/22
The Address section allows you to assign an identification number of the position
in which it will be installed (1-1023) and an identification number of the equipment
itself (1-63). This allows to the RDS to recognize only the messages for all and
those addressed to him personally. If a device is configured as a Site=9 and
equipment=5 it will be recognized itslef on 4 addresses.
Address 1: Site = 0 Equipment = 0
Address 2: Site = 9 Equipment = 0
Address 3: Site = 0 Equipment = 5
Address 4: Site = 9 Equipment = 5
The R.T.C. section allows you to set the time and enable the clock transmission
through the 4A groups to minute change.
The “RTC ON/OFF” button enables or disables the time transmission time.
The “Use PC” button forces the PC to send the time system instead that one set
by the user in the text field above.
The offset is relative to the time zone at meridian 0, in steps of 30 minutes.
In countries like Italy, where the whole territory is within the same time zone, is
indifferent to put “the GMT with 1” or “local time with 0”.
The “RDS ON / OFF” button switches on and switches off the 57KHz RDS carrier.
On the equipment based on TRDSP4 there is only one level for the RDS carrier
and a single phase, which can be set through the “A / B” and “Sync MPX” fields.
The conversion mV ◄► dB is done in real-time by the program, so the user can
choose to change the field that prefers.