R&M Materials Handling, Inc
STAGEMAKER
®
COMPACT Concert Hoist
Springfield, Ohio USA
SM10 Installation & Maintenance Manual
: 800 955-9967
web:
www.rmhoist.com
June 2006
5 June 2006 26 SM10-M & I MANUAL - 2006 - 0.doc.
MAXIMUM CABLE LENGTH – FEET
------------------------
[MAXIMUM NOMINAL CURRENT – AMPS]
SM10-208V
CABLE
SYSTEM
12AWG
14AWG
16AWG
ONE HOIST (HOIST: A)
58 FEET
[ 7.8 AMPS ]
36 FEET
[ 7.8 AMPS ]
23 FEET
[ 7.8 AMPS ]
TWO HOISTS (HOISTS: B+C)
29 FEET
[ 7.8 AMPS ]
------------- -------------
NOTE: IF ANY CIRCUIT HAS TWO (2) WIRE SIZES, USE SMALLER WIRE SIZE VALUES
MAXIMUM CABLE LENGTH – FEET
------------------------
[MAXIMUM NOMINAL CURRENT – AMPS]
SM10-230V
CABLE
SYSTEM
12AWG
14AWG
16AWG
ONE HOIST (HOIST: A)
74 FEET
[ 7.2 AMPS ]
46 FEET
[ 7.2 AMPS ]
29 FEET
[ 7.2 AMPS ]
TWO HOISTS (HOISTS: B+C)
37 FEET
[ 7.2 AMPS ]
23 FEET
[ 7.2 AMPS ]
-------------
NOTE: IF ANY CIRCUIT HAS TWO (2) WIRE SIZES, USE SMALLER WIRE SIZE VALUES