Section I V– Operating Procedures
Basic
Controls:
1)
MENU
- This button scrolls through the set
parameters as indicated by the LED lamps to the left, in
the following order:
a) System Pressure (default)
b) Discharge
Temperature
c) Running Hours; Shows 'run' followed by the hours in
alternating form.
d) Loaded Hours; Shows 'load' followed by the hours in
alternating form.
e) Separator Hours: 'SEPA', followed by the hours in
alternating form.
f)
Air Filter Hours; shows 'AIr.f' followed by the hours in
alternating form.
f)
Fluid Filter Hours; shows 'Flu.f' followed by the hours
in alternating form.
g) Fluid Service/Sample Hours; ' FLu' followed by the
hours in alternating form.
2)
START
will start the compressor, if no fatal faults are present (open sensor or overloads etc).
NOTE
:
The
RUN STATUS LED
will be
ON
to show that a start cycle is in progress. The compressor will not
start if the line pressure is above the load point; the compressor will start when the line pressure
drops below the load point. If the compressor is waiting to start, the 'Run Status' LED will flash
rapidly.
3)
STOP
will initiate a controlled stop on the compressor. The stop cycle will take about 5 seconds to
complete, as the system has to unload and blow-down prior to halting the motor.
4)
UP
and
DOWN
are used to select parameters in the setup menus.
5)
RESET
is used to clear fault or service conditions from the display panel.
System
Indicators:
RUN STATUS
indicates that the compressor is in a run state. Steady indicates that the compressor is
running. If this light is
flashing
, and the compressor is in a stopped condition, the compressor will
re-
start at any time
. This also indicates that the compressor is about to start, when the auto-restart option
is enabled.
LOAD/UNLOAD:
The left-most digit on the numeric display will show 'L' when the compressor is
loaded, and 'U' when unloaded.
Quincy Compressor – QSF Series
18