Section V– Servicing
QGV-200 Separator Installation
The 200 horsepower model utilizes an inside/out flow requiring the separator seal to be located on the
inlet to the separator. The sealing surface is located inside the pressure vessel and is coated to prevent
corrosion. Remove any loose material prior to separator installation.
After the continuity verification procedure is complete, install the separator as follows:
1. Lubricate the separator o-ring with compressor fluid and place separator inside the reservoir with o-ring
end facing down, centered inside studs.
2. Place the square separator compression plate over the 4 studs.
3. Install the (4) Nylok nuts on studs and tighten as follows:
Turn nuts down until they’re touching the compression plate. Do not over compress o-ring.
Tighten nuts by turning clockwise ½ turn in a cross pattern. Over tightening the compression plate will
deform the separator, reducing performance.
SEPARATOR
RETAINING PLATE
THREADED ROD
&
NYLOK NUT
QGV-200 Separator Installation
Quincy Compressor – QSF Series
30