Section II – Description
! WARNING !
Never remove, bypass or tamper with this HAT switch. Failure to provide
this safety feature could cause death, serious injury and/or property
damage. If the compressor is shutting down due to high discharge
temperature, contact a qualified service technician immediately.
Indicators
Main Power Light On
Indicates power from the main disconnect switch has been turned on and there is live power at the
compressor starter and control panel. This light will remain on as long as there is power to the unit.
! CAUTION !
Always check power supply disconnect. The Power-on light may be
inoperable.
High Discharge Air Temperature Light
Indicates the unit has sensed an unusually high discharge temperature.
Motor Overload Fault
Indicates excessive over amp of drive motor and fan motor if air-cooled.
Fluid Filter Change Light
This is used to determine fluid filter change intervals on the QSF, as programmed by the operator. It
also indicates excessive pressure differential across the fluid filter on the standard QSF.
Air/Fluid Separator Element Change Light
This is used to determine separator element change intervals on the QSF, as programmed by the
operator. It also indicates excessive pressure differential across the air/fluid separator element on the
standard QSF.
Air Intake Filter Change Light
This indicator signals when the filter element needs to be cleaned or replaced on the QSF.
NOTE:
Both the standard and stock versions include a programmable change interval timer on the air filter, fluid
filter and the air/fluid separator element.
Quincy Compressor – QSF Series
9