Section VII– Troubleshooting
PROBABLE CAUSE
CORRECTIVE ACTION
Excessive Water Content in Fluid
Water drain intervals
Drain water as needed to reduce water content in fluid below 200
PPM.
Discharge temperature too low
Check operation of thermostatic valve or water regulating valve. If
condition continues, consult factory service department.
Pressure Relief Valve Exhausting
Differential pressure regulator not
set correctly
Adjust differential pressure regulator to obtain desired modulation
range.
Air pressure not set correctly
Readjust air pressure switch so that the compressor unloads at the
desired pressure.
Air inlet valve not closing properly
in relation to air demand
Correct in accordance with the instruction in “Inlet valve not opening
or closing in relation to air demand” section of this troubleshooting
guide.
Plugged separator
Replace with new air/fluid separator
Faulty receiver pressure gauge
Check gauge for accuracy and replace if necessary. Adjust control
settings.
Faulty pressure relief valve
Check pressure relief valve for correct pressure setting. If valve is still
leaking, replace with new relief valve.