Section III - Controller
28
Quincy Compressor
Element 2 is shutdown due to repeatedly high
element temperature warnings
If this occurs:
1. Switch off the voltage and remedy the problem cause.
2. Switch on the voltage and reset the element manually by selecting the warning icon
(or go to warning menu - elements) and press Reset:
Warning element screen (element 2 is triggered)
Text on image
(1)
Element(s)
(2)
Warning Element 2
(3)
Triggered
(4)
Problem Element
(5)
More
(6)
Reset
Each time an element is reset manually, this will be logged in the Element Problem Reset
counter: