Section III - Controller
16
Quincy Compressor
CAUTION!
If the function is activated and provided the regulator was in the automatic operation
mode, the compressor will automatically restart if the supply voltage to the module
is restored within the programmed time interval.
Control panel
Parts and functions
Reference
Designation
Function
1
Display
Shows the compressor operating condition and a
number of icons to navigate through the menu.
2
Pictograph
Automatic operation
3
Pictograph
General alarm
4
Alarm LED
Flashes in case of a shutdown, is lit in case of a warn-
ing condition.
5
Pictograph
Service
6
Service LED
Lights up if service is needed
7
Automatic operation LED
Indicates that the regulator is automatically control-
ling the compressor.
The compressor is stopped and restarted
8
Voltage on LED
Indicates that the voltage is switched on.
9
Pictograph
Voltage
10
Enter key
Use this button to confirm the last action.
11
Escape key
Use this button to go to previous screen or to end
the current action.
12
Scroll keys
Keys to scroll through the menu.
13
Stop button
Button to stop the compressor. LED (7) goes out.
14
Start button
Button to start the compressor. LED (7) lights up indi-
cating that the controller is operative.