13.7.1 Water Level Management
The sight tube on the rear of the tank and the electronic Water Level Indicator both display the
water level in the onboard tank. A low water warning will alert the operator when the water tank
reaches 25% of its capacity. When the low water alert activates, there will be about 750 litres of
water remaining.
The low water alerts on the body and the pump control panel will only operate when the pump
ignition is active to prevent lights and warning alarms from causing a distraction to other road users
when the appliance is returning to refill. Vehicle Ignition On;
Electronic Water Level Indicator Display at the Pump Control Panel
Mini Water Level Indicator in the Cabin
Cabin Low Water Alarm
Vehicle Ignition and Pump Ignition On:
Electronic Water Level Indicator Display at the Pump Control Panel
Mini Water Level Indicator in the Cabin
Cabin Low Water Alarm
Low Water Strobe will activate at 25% tank capacity.
Warning Buzzers at the Cabin Centre Console and the Pump Control Panel will activate at
25% tank capacity.
Buzzer mute conditions:
Press the buzzer mute button in the Pump Control Panel or the Cabin Centre Console to
stop the low water alarm in the respective location.
The buzzer in the Pump Control Panel will reset when the pump ignition turns off, or the
water rises above 75% or fuel rises above 25%.
The buzzer in the Cab Centre Console will reset when the vehicle ignition turns off.
Vehicle Ignition On and Pump Ignition Off:
Electronic Water Level Indicator Display at the Pump Control Panel
Mini Water Level Indicator in the Cabin
The buzzer in the Cabin Centre Console will activate when levels are below 25%.
Figure 87: Water Level Indicator
Table 36: Water Level Indicator
Item Label
Item Name
1
Cabin Mini Water Level Display
2
Pump Control Panel Water Level Display
1
2