35
User and installation guide Room Temperature Controller with Limiter
1. Principle of operation
The programmable temperature controller QuickTherm HF Room Thermostat Smart allows programming switching events (up to 9) and temperatures
according to personal needs. After installation the device automatically shows the time of day and the room temperature. In AUTO mode, the heater will be
automatically activated according to programmed time and temperature. Program 1 is the default pre-set program (see 8.).
Room temperature will be controlled, the floor temperature will be limited (measured by the remote sensor). The heater will be switched on when the
temperature drops below the current set-point.
In case of function „Min Floor Temp“ (H3) it will be heated if the floor temp drops below the set min-value. This is even when the room temp. is too high.
In case of function „Max Floor Temp“ (H3) heating will be stopped if the floor temp exceeds the set max-value. This is even when the room temp. is too low.
Actual Day
Actual Floor Temperature
Calling for Heat (Blinks if detached from power module or there is no mains power)
Helping text
Mode = AUTO
Time = 14:31
2. Installation
Caution!
The device may only be opened and installed according to the circuit diagram on the device or these instructions by a qualified electrician.
The existing safety regulations must be observed.
Appropriate installation measures must be taken to achieve the requirements of protection class II.
This device, is used to control the temperature only in dry rooms, under normal environmental conditions. This electronic device conforms
to EN 60730, It is an “independently mounted control” and works according to operating principle 1C.
Summary of Contents for QuickTherm HF