OPERATION / MAINTENANCE / TECHNICAL DATA
EN
9
QUICK SPA
QCC-DRV CH4 - REV001A
Quick
®
reserves the right to modify the technical
characteristics of the equipment and the conten-
ts of this manual without prior notice.
In case of discordance or errors in translation
between the translated version and the original
text in the Italian language, reference will be
made to the Italian or English text.
Wiring, terminals and cables
Considering the high currents involved, a few precautions on wiring are in order:
• DMX cable length should not exceed 100 m.
• Cable size should range from 0.5 mm
2
to 1.5 mm
2
• Peel off cables by 8 mm to add the terminal.
OPERATION
The QCC-LCS TP interface connected to the power supply permits managing an RGBW system. The functions are activated
and the instructions are sent to the DMX512 output by means of a touch pad.
FUNCTIONS
ON-OFF Key: Briefly press it to switch on/off the touch pad and all the light zones connected. Press and hold this key to
enable/disable the sounds when a key is pressed.
MODE Key: Press this key briefly to change the operation mode selecting among eleven options, divided into static and
colour change:
• static options: 1-Red, 2-Green, 3-Blue, 4-Yellow, 5-Purple, 6-Cyan, 7-White;
• colour change options: 8-RGB skip, 9-All color skip, 10-RGB fade, 11-All color smooth.
Tasto Brightness/Speed: Used to change light intensity in all static operation modes and to change the execution speed
in the colour change operation modes.
Colour selection key: Used to modify the colour of the light zone in the colour change operation modes.
Zone shift keys: You can select up to four light zones. The blue LED lit next to each key indicates that the light zone is ready
to be modified. Press and hold one of the keys to turn on/off the relevant light zone.
RGBW tastes: Used to adjust the light intensity of each colour. Specifically, key “W” manages the white channel differently
than the rest of the keys: Press it briefly to turn the W channel on/off; press and hold to change the intensity of the W
channel.
F
F
TECHNICAL DATA
QCC-LCS TP USER INTERFACE CONNECTIONS
See connection diagram on page 17
CLEANING
The device requires no special cleaning procedure. Clean the front using a damp cloth, avoiding corrosive substances.
Do not apply liquids directly on the unit; they might penetrate and damage the device.
DISCONNECT THE POWER SUPPLY BEFORE CLEANING THE UNIT.
WARRANTY
Failure to comply with the prescriptions below will void the Warranty.
MODEL
QCC-LCS TP
INPUT CHARACTERISTICS
Power supply
10 ÷ 30 Vdc
Power consumption
30mA
Control Output
DMX512
GENERAL CHARACTERISTICS
Operating temperature
from -20°C to +60°C
Storage temperature
from -40°C to + 70°C
Relative humidity
80% senza condensa
Housing protection
IP 40
Certifications
CE marking