background image

38

CHC1103 IT EN FR - REV001A

EN

SYSTEM FAULT

Up alarm

This fault is displayed if the length of the chain is less than the value set on the FUNCTIONS\UP 

ALARM menu.

No sensor

This fault is displayed if the laps sensor does not detect the gypsy movement within four seconds 
(for a longer time if auto free fall management is activated) when key 

p

, or 

q

 (UP or DOWN ) of 

the chain counter or other switches are pressed. 

Check the distance between the magnet and sensor, operation of the laps sensor and the wiring/

connections. 

Sensor failure

This fault is displayed if the chain counter detects a short circuit in the sensor for more than four 
seconds (for a longer time if auto free fall management is activated) when key 

p

, or 

q

 (UP or 

DOWN ) of the chain counter or other switches are pressed.

Check operation of the laps sensor and the wiring/connections. 

PROBLEMS WITH MANUAL RESET

These problems are reset by the user:  by pressing key 

=

 (SELECT) or turn off the chain counter and turn it back on.  If 

the fault is present keys 

p

,

q

 (UP, DOWN) are disabled.

UP ALARM

35.3

M

SPEED

0M/M

NO SENSOR

35.3

M

SPEED

0M/M

SENSOR FAILUR

35.3

M

SPEED

0M/M

Overload

This fault is signaled when the instrument detects at short circuit or overload at the instrument’s 

output.

Check wiring of signals UP and DOWN and absorption of the points of use connected to the output 

of the instrument.
If there is a fault, keys 

p

,

q

 

(UP, DOWN) are inoperative.

OVERLOAD

35.3

M

SPEED

0M/M

ANCHOR RECOVERY MODE

The mode allows bypassing NO SENSOR or SENSOR FAILUR errors in order to allow chain operation.  

This mode can be activated when the instrument reports NO SENSOR or SENSOR FAILUR by simultaneously pressing the 

p

 and 

q

 buttons (UP and DOWN) for at least two seconds.

Once activated, the wording "SENSOR PROTECT DEACTIVATED" will be displayed:

SENSOR PROTECT
DEACTIVATED

SPEED

0M/M

The 

p

 and 

q

 buttons (UP and DOWN) are again enabled.

At this point, the “AUTOMATIC DOWN” and “UP ALARM” functions are inhibited.

WARNING: 

even if bypassed, the problem persists and must be resolved as soon as possible.

WARNING:

 use the “ANCHOR RECOVERY MODE” only when strictly necessary, since the instrument will not display the 

count of the dropped chain and consequent position of the anchor.

This mode is reset by switching the instrument off and on.

Summary of Contents for CHC1103

Page 1: ...Quality Nautical Equipment ALLARM SALITA 1 5M VELOCITA 0M M Manuale di installazione ed uso CONTA CATENA CHC1103 Manual of installation and use CHAIN COUNTER CHC1103 Manuel d installation et d emploi...

Page 2: ......

Page 3: ...window Pag 29 CHAIN COUNTER OPERATION Windlass electric drive Free fall Pag 30 CHAIN COUNTER OPERATION Turning the torch On and Off Monitoring Winch mode Pag 31 SETTING THE CHAIN COUNTER The structure...

Page 4: ...di discordanze o eventuali errori tra il testo tradotto e quello originario in italiano fare riferimento al testo italiano o inglese Questo dispositivo stato progettato e realizzato per essere utiliz...

Page 5: ...llante adatto per materiali metallici resistente all ambiente salmastro e in grado di sopportare temperature da 30 a 80 C tipicamente rispondono a questi requisiti alcuni collanti epossidici bi compon...

Page 6: ...n qualsiasi apparecchio radio ricevente 1 m da qualsiasi apparato radiotrasmittente escluso SSB 2 m da qualsiasi apparato radiotrasmittente SSB 2 m dal percorso del fascio radar Dopo aver scelto dove...

Page 7: ...lsiasi apparato radiotrasmittente escluso SSB 2 m da qualsiasi apparato radiotrasmittente SSB Seguire le regole riportate di seguito per la realizzazione dell impianto elettrico relativo allo strument...

Page 8: ...arla completamente Disconnessione dello strumento Ruotare la ghiera della spina in senso antiorario ed estrarla Coprire la presa con l apposito coperchio ruotando la ghiera in senso orario ATTENZIONE...

Page 9: ...essere impostato come SLAVE Lo strumento CHC1103 deve essere impostato come MASTER solo se l unico strumento presente Il compito dello strumento MASTER quello di allineare la misura di catena calata...

Page 10: ...di misura Riga di monitoraggio FUNZIONAMENTO DELLO STRUMENTO L interfaccia tra l utente e lo strumento avviene grazie a tre elementi IL DISPLAY GRAFICO LA PULSANTIERA E L AVVISATORE ACUSTICO BUZZER S...

Page 11: ...oppure attivando la salita da un comando esterno ausiliario oppure spegnendo lo strumento Discesa automatica Questa funzione pu essere utilizzata solo se stata precedentemente impostata ed attivata n...

Page 12: ...una finestra simile a questa Se lo strumento spento in modalit di tonneggio alla ri accensione torner alla visualizzazione della velocit di movimento della catena ARRESTO TONNEGGIO STOP ATTIVATO TONNE...

Page 13: ...A AUTO CONTRASTO ILLUMINAZIONE TEMPO ILLUMINA SUONO TASTI ENGLISH ITALIANO FRANCAIS DEUTSCH ESPANOL UNIT MISURA GIRO BARBOTIN NUMERO MAGNETI TEST SENSORE TEST LCD INFO UNIT DATI FABBRICA CONTROL FLASH...

Page 14: ...atena non in grado compensare l inerzia meccanica del salpa ancora il bar botin pu ruotare nel senso della salita immediatamente dopo la disattivazione del comando Considerare questo fattore nella sce...

Page 15: ...one del display Il ritardo ha inizio a partire dal rilascio dell ultimo pulsante o dal termine della CADUTA LIBERA ILLUMINAZIONE IMPOSTA VALORE 4 TEMPO ILLUMINA IMPOSTA VALORE 30 S I valori selezionab...

Page 16: ...di magneti installati sul barbotin NUMERO MAGNETI IMPOSTA VALORE 1 GIRO BARBOTIN IMPOSTA VALORE 10 0 CM I valori selezionabili sono da 1 a 16 impostazione di fabbrica 1 Se l unit di misura impostata M...

Page 17: ...ri contati NUMERO MAGNETI 1 GIRO BARBOTIN inc 240 numero di giri contati NUMERO MAGNETI 1 Dopodich sar mostrata per due secondi la seguente finestra e si ritorner al men IMPOSTAZIONI CALIBRAZ AUTOM FI...

Page 18: ...esta funzione visualizza alcune informazioni sullo stato di trasmissione dei messaggi CAN MENU IMPOSTAZIONE CONFIGURAZIONE CAN Tramite queste opzioni possibile impostare la priorit CAN e la velocit de...

Page 19: ...VELOCITA 0M M STOP PROBLEMI DI SISTEMA Di seguito si riportano i problemi di sistema che compaiono nella riga di stato suddivisi in tre categorie problemi con reset automatico problemi con reset auto...

Page 20: ...i ALLARM SALITA 35 3M VELOCITA 0M M MANCASENSORE 35 3M VELOCITA 0M M SENSORGUASTO 35 3M VELOCITA 0M M Carico elevato Il problema segnalato nel caso in cui lo strumento rilevi un corto circuito o un so...

Page 21: ...ssimo livello torcia accesa e salpancora attivato 4 Con temperature inferiori a 0 C i cristalli del display LCD rallentano il loro movimento 5 Con la spina correttamente inserita nella presa Esclusa l...

Page 22: ...in translation between the translated version and the original text in the Italian lan guage reference will be made to the Italian or English text This device was designed and constructed for use on r...

Page 23: ...ding temperatures ranging from 30 to 80 C Generally speaking some epoxy based bi component glues satisfy these requirements Several magnets can be installed on the same gypsy to increase the precision...

Page 24: ...adio receivers 1 m away from any radio transmitters except for SSB 2 m away from any radio transmitters SSB 2 m away from the path of the radar beam After selecting the area where the instrument is to...

Page 25: ...away from cables that transmit radio signals except for SSB radio transmitters 2 m away from cables for SSB radio transmitter signals Follow the safety precautions and directions given below when mak...

Page 26: ...y tightened Disconnecting the instrument Turn the plug s ring nut counter clockwise and take it out Cover the socket with the cover provided turning the ring nut clockwise ATTENTION make certain the s...

Page 27: ...only instrument present The task of the MASTER chain counter is to align the length of the chain lowered and the operating parameters of all the SLAVE chain counters The MASTER therefore is used as a...

Page 28: ...ea Monitor line CHAIN COUNTER OPERATION Three elements are employed between user and counter interface A GRAPHIC DISPLAY CONTROL KEYS AND BUZZER The graphic display screen shows the measure of chain l...

Page 29: ...activating the up function from an external device from another chain counter or other control or by shutting off the chain counter Automatic down function This function can be used only if it was pr...

Page 30: ...instrument will display a window like this If the instrument is turned off in winch mode when turned on again it will display the speed of chain movement STOP WINCH STOP ACTIVATED WINCH MONITORING The...

Page 31: ...EXIT UP ALARM AUTO DOWN CONTRAST LIGHT LIGHT DELAY KEY BEEP ENGLISH ITALIANO FRANCAIS DEUTSCH ESPANOL SET MEASURE GYPSY LAP MAGNETS NUMBER SENSOR TEST LCD TEST DEVICE INFO SET DEFAULT CHECK FLASH CHE...

Page 32: ...e to compensate for mechanical inertia of the windlass the gypsy can rotate upward direction as soon as the command has been inactivated Take this factor into consideration when setting the up alarm v...

Page 33: ...ighting of the display screen The delay time starts to elaps as soon as the last key is released or when FREE FALL is completed LIGHT SET VALUE 4 LIGHT DELAY SET VALUE 30 S Selectable values OFF 1 2 3...

Page 34: ...talled on the gypsy MAGNETS NUMBER SET VALUE 1 GYPSY LAP SET VALUE 10 0 CM Selectable Values 1 to 16 default 1 If the unit of measurement is set to METERS the settable values are from 0 1 to 999 9 cm...

Page 35: ...NUMBER OF MAGNETS 1 GYPSY LAP inc 240 number of laps counted NUMBER OF MAGNETS 1 After which the following window will be displayed for two seconds and the SETTINGS menu will be shown again AUTO CALI...

Page 36: ...n shows some information regarding CAN messages transmission state SETTINGS MENU CAN CONFIGURATION These options allow setting CAN priority and CAN bus interface speed SETTINGS MENU CAN CONFIGURATION...

Page 37: ...N ERROR 35 3M SPEED 0M M STOP SYSTEM FAULTS System faults that appear on the state line divided into three categories which are shown below problems with automat ic reset problems with automatic reset...

Page 38: ...bled UP ALARM 35 3M SPEED 0M M NOSENSOR 35 3M SPEED 0M M SENSORFAILUR 35 3M SPEED 0M M Overload This fault is signaled when the instrument detects at short circuit or overload at the instrument s outp...

Page 39: ...ck lighting off and windlass not on 3 Typical value with back lighting on at highest level and windlass on 4 With temperatures below 0 C the crystals in the LCD slow down 5 With the plug correctly ins...

Page 40: ...ATTENTIVEMENT CE MANUEL DE L UTILISATEUR DANS LE DOUTE CONSULTER LE REVENDEUR QUICK En cas de discordances ou d erreurs ventuelles entre la traduction et le texte original en italien se r f rer au te...

Page 41: ...au de mer On conseille d utiliser des colles poxy deux composants On peut installer plusieurs aimants sur le m me barbotin pour augmenter la pr cision de l instrument pas fournis Placer les aimants le...

Page 42: ...pteur 1 m de tout appareil radio de transmission except SSB 2 m de tout appareil radio de r ception et transmission SSB 2 m du parcours suivi du faisceau radar Apr s avoir choisi l emplacement de l in...

Page 43: ...cette raison l l appareil doit se trouver au moins 1 m des c bles des signaux radio except les appareils radio de r ception et de transmission SSB 2 m des c bles des signaux radio pour appareils de r...

Page 44: ...jusqu ce qu il soit serr fond D branchement de l instrument Tourner l embout de la fiche dans le sens anti horaire et l enlever Couvrir la prise avec le couvercle pr vu cet effet en tournant l embout...

Page 45: ...doit tre programm comme SLAVE L instrument CHC1103 ne doit tre programm comme MASTER que s il est le seul instrument pr sent Le but de l appareil MASTER est de comparer la mesure de la cha ne descend...

Page 46: ...mesure Ligne de contr le FONCTIONNEMENT DE L APPAREIL L interface entre l utilisateur et l appareil est constitu e d un CRAN GRAPHIQUE DU TABLEAU DE COMMANDE ET DE L AVERTISSEUR SONORE L cran graphiqu...

Page 47: ...touche mont e d une commande externe d un autre compteur de cha ne ou si on teint l appareil Dans certaines situations on peut mouiller l ancre en tenant compte du fait que le guindeau peut la faire...

Page 48: ...e celle ci Si l instrument est teint en mode poup e seule au rallumage il se r f rera ou vitesse de la cha ne ARRET POUPEE SEULE STOP ACTIVE POUPEE SEULE SURVEILLANCE Le type d information pr sent sur...

Page 49: ...contraste r tro illumination cran temps de l illumination r tro avis sonore lorsqu on presse sur les touches sonores verrouillage temporaire des boutons poussoirs p et q UP et DOWN LANGUE S lection d...

Page 50: ...ionne pas si la mont e est contr l e par une quelconque commande externe auxiliaire ATTENTION le compteur de cha ne ne peut pas compenser l inertie du guindeau le barbotin peut tourner dans le sens de...

Page 51: ...eurs que l on peut entrer sont 30S 60S 90S 120S 180S 240S ACTIVE toujours clair le calibrage d usine est 30 S Utiliser cette option pour activer ou d sactiver le son lorsque l on appuie sur les touche...

Page 52: ...NTS ENTRER VALEUR 1 TOUR BARBOTIN ENTRER VALEUR 10 0 CM Les valeurs utiliser sont de 1 16 calibrage d usine est 1 Si l unit de mesure est exprim e en METRES les valeurs sont de 0 1 999 9 cm calibrage...

Page 53: ...ich e pour deux secondes Et on revient au menu REGLAGES CALIBRAGE AUTO FIN DE PROCEDURE MENU REGLAGES CONTROLES Gr ce cette option on peut effectuer les proc dures de contr le pour v rifier le fonctio...

Page 54: ...utilis e pour afficher certaines informations sur la transmission des messages CAN MENU REGLAGES CONFIGURATION CAN Ces options permettent de configurer la priorit CAN et la vitesse de l interface CAN...

Page 55: ...EME Les anomalies du syst me affich es sur la ligne d tat sont divis es en trois cat gories probl mes avec remise en service automatique probl mes avec remise en service automatique et blocage des tou...

Page 56: ...sactiv es ALARMEMONTEE 35 3M VITESSE 0M M MANQCAPTEUR 35 3M VITESSE 0M M DEFCAPTEUR 35 3M VITESSE 0M M Surcharge Le probl me est signal dans le cas o l instrument d tecte un court circuit ou une surch...

Page 57: ...leur typique avec illumination r tro activ e au niveau max et guindeau allum 4 Avec temp ratures inf rieures z ro les cristaux de l afficheur LCD ralentissent leur mouvement 5 Avec la fiche correcteme...

Page 58: ...58 CHC1103 IT EN FR REV001A DIMENSIONI DIMENSIONS mm inch 165 6 1 2 59 1 2 21 64 41 6 1 41 64 62 2 2 29 64 49 4 1 15 16 185 7 9 32...

Page 59: ...20 SWITCH FUSE 4A FAST GYPSY OPTIONAL CHC1103 CHAIN COUNTER CHC1203 CHAIN COUNTER FNCH3CC00500A00 0 5M CHC3 CAN CABLE SENSOR CONTACTOR UNIT REVERSING CONTACTOR UNIT AUXILIARY COMMAND BATTERY 12 24 V G...

Page 60: ...60 CHC1103 IT EN FR REV001A NOTES...

Page 61: ...61 61 CHC1103 IT EN FR REV001A SOCKET FOR HRC...

Page 62: ...NOTES...

Page 63: ......

Page 64: ...e del prodotto Product code and serial number Code et num ro de s rie du produit EN IT CHC1103 CHAIN COUNTER FR QUICK S p A Via Piangipane 120 A 48124 Piangipane RA ITALY Tel 39 0544 415061 Fax 39 054...

Reviews: