Factory parameters preset
With the PRESET operation, the TermoPID control unit can be reconfigured
with the default parameters (factory data).
To perform the PRESET, proceed as follows:
-
With the termopid disabled. press
▼.
-
Power the board.
-
When the display shows
“
prs
” release the key.
-
Cut-out the power to the board.
The factory data (default) is the following:
F01 - °C
F02
– 6
P1
– 1,5
I1
– 0,0
D1
– 1,5
B1
– 10
P2
– 1,5
I2
– 0,0
D2
– 1,5
B2
– 6
T1
– 95
T2
– 124
E1
– 15
E2 - 0
Alarms
In the case of a sensor failure, on the display the caption A1 (or A3 for the
Vetrano model) is shown: the adjustment and programming outputs are
disabled.
In the case of a sensor short circuit, on the display the caption A2 (or A4 for the
Vetrano model) is shown: the adjustment and programming outputs are
disabled.
Termopid Setting and Functioning model CAROLA
With this TERMOPID model, the set pont temperature adjustment is through the
position of the micro switch as shown below.