Product function description:

Function

Indication

Description

Standby 

status

The red LED flashes 

every 40 seconds. 

The unit is working.

Low battery 

warning

The unit chirps with 

red LED flashing every 

40 seconds. 

The battery is under 

low battery 

s

tatus, 

please replace the 

smoke alarm device.  

Fault 

warning

The unit chirps between

the red LED two times 

flashing. 

The unit is faulty, get 

help from the 

section: 

“Trouble Shooting”. 

Self-test 

fault warning

 

 

The red LED flashes 

twice every 40 seconds. 

The buzzer fault or 

buzzer detection 

circuit fault.   

 

Test function The red LED flashes 

once every second with 

alarm sounding until

the TEST button is 

released.  

l

Test by pressing the

TEST button on the 

smoke alarm at least 

3 seconds. 
The alarm will sound 

if all electronic 

circuitry, horn and 

battery are working 

properly.  
If no alarm sounds, 

refer to 

“Trouble Shooting”

l

l

Summary of Contents for Simline QSP10

Page 1: ...velop in different ways and are often unpredictable For maximum protection against fast flaming fires and slow smouldering fires both ionisation and photoelectric alarms should be installed Copyright 2020 carrier All rights reserved Chubb Fire and Security Pty Ltd is part of the Carrier Global Corporation NYSE CARR group of companies Quell is a registered trademark of Chubb Fire Security Pty Ltd ...

Page 2: ...eep thismanual near the alarm for future reference 1 Manufactured in China for Chubb Fire Security Pty Ltd Building F Unit 1B 3 29 Birnie Ave Lidcombe NSW 2141 Australia Telephone 1800 654 435 Website www quell com au 2 Troubleshooting 14 Product Specifications Power Supply DC 3V Battery Spec CR123A Battery Lifetime 10 years Alarm Sensitivity 0 100 0 160 dB m Alarm Volume 85dB A 3m Operating Tempe...

Page 3: ...door may prevent an alarm located outside from waking the sleeper In the immediate area of bedrooms and the exit path from all sleeping areas Figure 1A In stairways as stairways act like chimneys for smoke and heat In any room where large electrical appliances are operated e g portable heaters or humidifiers If a hallway or room is more than 9 1m long put alarms at both ends For maximum household ...

Page 4: ...eiling Figure 2B Smoke alarms in rooms with ceiling slopes greater than 1m in 8m horizontally should be located on the high side of the room Figure 2B 2 For Wall Mounting When mounting the alarm on the wall use an interior wall with the top edge of the alarm at a minimum of 10cm and mixinum of 30cm below the ceiling Figure 2A ...

Page 5: ...ctric Type Smoke Alarms for Additional Protection KITCHEN BEDROOM BEDROOM BEDROOM LIVING ROOM KITCHEN BEDROOM BEDROOM HALL BASEMENT FIGURE 1A FIGURE 1C FIGURE 1B SINGLE FLOOR PLAN MULTIPLE FLOOR PLAN BEDROOM FAMILY ROOM WORKSHOP BASEMENT KITCHEN HALL GARAGE MASTER BEDROOM FIRE EXTINGUISHERS SMOKE ALARMS FIRE BLANKET TOTAL HOME PROTECTION 2 ...

Page 6: ...llation Figure 2A 2 Figure 2B NOT IN THIS AREA ANYWHERE IN THIS AREA NOT IN THIS AREA ANYWHERE IN THIS AREA PEAK CEILING SLOPED CEILING 500mm 1000mm 1000mm 500mm DEAD AIR DEAD AIR DO NOT INSTALL DO NOT INSTALL ...

Page 7: ...cause nuisance alarms 6 In insect infested areas 7 Smoke alarms should not be installed within 3 foot 0 9m of the following the door to a kitchen the door to a bathroom containing a tub or shower forced air supply ducts used for heating or cooling ceiling or whole house ventilating fans or other high air flow areas 8 Kitchens Normal cooking may cause nuisance alarms If a kitchen alarm is desired i...

Page 8: ...this Insert the screws into the mounting plate and tighten them firmly into the plugs Place the smoke alarm on the mounting bracket and secure it by turning it clockwise Test the correct operation of your smoke alarm by pressing the test button If no sound is generated the smoke alarm is not functioning properly and should not beused WARNING To prevent injury this unit must be securely attached to...

Page 9: ...8 Installation 2 ...

Page 10: ...etween the red LED two times flashing The unit is faulty get help from the section Trouble Shooting Self test fault warning The red LED flashes twice every 40 seconds The buzzer fault or buzzer detection circuit fault Test function The red LED flashes once every second with alarm sounding until the TEST button is released l Test by pressing the TEST button on the smoke alarm at least 3 seconds The...

Page 11: ...ce feature If cooking or other non hazardous sources cause the alarm to sound it can be temporarily silenced by pressing the test button The alarm enters silence mode for 10 minutes After the 10 minute dormant period the smoke alarm will resume normal operation Fire alarm The Red LED flashes every second with alarm sounds Generate alarm sounds when fire happening Product function description Funct...

Page 12: ...st your alarm you could damage the alarm or ignite combustible materials and result in a fire l If the alarm sound and it is not being tested it means the unit detected smoke THE SOUND OF THE ALARM REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION Night mode This smoke alarm has an automatic night mode In dark rooms the led the led signal will be dimmed to prevent disturbance of the night s sleep Alarm...

Page 13: ...12 2 Operation ...

Page 14: ...larm body from the bracket Disassembling Instructions 2 Activation To activate the alarm install the alarm on the mounting bracket The alarm will make a beep sound indicating that the product is activated successfully Firmly press the test button for at least 3 seconds The alarm will sound 3 short beeps 1 5 seconds pause then repeat it until release the button The alarm may sound for up to a few s...

Page 15: ...low battery status please replace the smoke alarm device Fault warning Clean the smoke alarm Self test fault warning Press the TEST button at least 15s then release False alarm Press the TEST button to silence it Clean smoke alarm device Move the smoke alarm device to new location The alarm sounds different from it is used to Ensure that the battery is not low voltage Clean smoke alarm If the unit...

Page 16: ... chirp approx every 40 seconds and the red LED flash once at the same time for a minimum of thirty days when the battery gets low If there is a defective battery or other failures you can refer to Trouble shooting for solution if there are still failures during warranty you can return to your retailer WARNING The battery is sealed in cover and not replaceable Please replace another new alarm if th...

Page 17: ... will not operate if the AC power has been cut off such as by an electrical fire or an open fuse Smoke alarms must be tested regularly to make sure the batteries and the alarm circuits are in good operating condition Smoke alarms cannot provide an alarm if smoke does not reach the alarm Therefore smoke alarms may not sense fires starting in chimneys walls on roofs on the other side of a closed doo...

Page 18: ...it including basements exception In existing one and two family dwelling units approved smoke alarms powered by batteries are permitted Smoke Detection Are more smoke alarms desirable The required number of smoke alarms might not provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke alarms For this reason it is recommended that...

Page 19: ...when the Alarm Sounds Alert small children in the home Leave immediately by your escape plan Every second counts so don t waste time getting dressed or picking up valuables In leaving don t open any inside door without first feeling its surface If hot or you see smoke seeping through cracks don t open that door Instead use your alternative exit If the inside of the door is cool place your shoulder...

Page 20: ...to be of acceptable quality and the failure does not amount to a major failure Exclusions Subject to non excludable laws this warranty does not cover normal wear and tear to the product or parts batteries or other consumables included with this product excluding sealed non replaceable battery models damage to the product caused by accidents misuse abuse lack of reasonable care tampering or repair ...

Page 21: ... a copy of the proof of purchase Also please make sure you have included an explanation of the problem If Quell elects to repair the product please note that goods presented for repair may be replaced by refurbished goods of the same type rather than being repaired Refurbished parts may be used to repair the goods 2 16 Australian Standard AS3786 2014 SAI Global Registered office 39 Talavera Road M...

Reviews: