3.2.
INTRO SET: QS-SB2 CONNECTION - 2 ACTUATORS
To connect QS-220-PL apply following steps:
1.
Plug Motion Lock Switch into Motion Lock ”ML UP” port in the QS-SB2 power cab-
inet.
2.
Connect M10 to M-BUS port in power cabinet using BUS communication cable at
both ends.
3.
Put M-BUS terminator (RJ45 plug with resistor) in second M-BUS port in the QS-SB2
power cabinet.
4.
Connect PC to the M10 controller using USB cable.
5.
Plug in the power cable with adequate type of plug into power socket in the QS-
SB2 power cabinet.
INFO
Order of connecting the cables is not important, keep the CFG switch according
to appropriate layout. Check section 3.4 and 3.5 for layout setup.