1. Non-professional personnel, do not remove the fittings in lamps and lanterns without permission. 

2. AC power supply: check whether the local power supply meets the rated voltage requirement. 

3. The lamps and lanterns is according to the type of electric shock protection design, lamps and 

lanterns should be used with sufficient power supply system grounding, and lamps and lanterns of 

the ground wire must be connected to the ground of the power supply system. Do not use insulation 

damaged power cord, at the same time, do not use the power cord overlap on the other wire. 

4. When the installation location and lamps and lanterns, any point on the surface of lamps and 

lanterns and any easy to burn the explosive keep minimum distance of 10 meters, 2.5 meters from 

irradiation distance, please do not install the lamps and lanterns is directly in to burn the material 

surface. 

5. Ambient temperature used in luminaires: (-10 d 40 degrees), the maximum temperature 

of the lamp surface is 80 degrees, and the lamps and lanterns should be kept away from the liquid 

material and wet environment. 

6. Make sure the lamps are well grounded before using the lamps, and do not install and remove 

any parts. 

7. When installing lamps and lanterns, the fixing screws must be fastened, equipped with safety 

cables and checked regularly. 

8. The continuous working time of the luminaires should not exceed 10 hours, and the interval time 

of continuous start of the lamps shall not be less than 10. Otherwise, the bulb should be protected 

from overheating and cannot be triggered normally. 

9. In the process of use, the lamp should be stopped using lamps in time. 

10. When the bulb reaches the rated service life, it should be replaced in time, or there will be a 

dangerous explosion. 

11. The rotating part of the lamp and the pasting accessories must be checked regularly and loos-

ened, and the shaking should be strengthened in time to prevent accidents. 

12. Lamps and lanterns uses strong wind cooling and accumulates dirt easily. Must be cleaned once 

a month especially the cooling tuyere otherwise will be in a dust jam, lead to bad heat dissipation.

Safety tips! 

To ensure your safe use of lamps, read the following safety tips carefully before 

using them to avoid unnecessary breakdowns and injuries. 

Summary of Contents for BEAM 7R

Page 1: ...230W BEAM English...

Page 2: ...ete ly solve X Y position Brighter 3 in combination with optical lens the color temperature reaches 8500K which is higher than 700W 1500W beam light and higher color temperature Lower Light bulb power...

Page 3: ...international standard control signal DMX512 2 The number of channels 16Ch 3 The number of motor a total of 10 mute motor 4 The X axis rotate for 540 the Y axis vertical rotation of 270 with automatic...

Page 4: ...ing installation must ensure that the lamps and lanterns is not tumbled down on the supporting frame and handle with a safety rope through the racks and lamps and lanterns assist hanging In order to e...

Page 5: ...d the lamps and lanterns should be kept away from the liquid material and wet environment 6 Make sure the lamps are well grounded before using the lamps and do not install and remove any parts 7 When...

Page 6: ...e for the current projection distance Four Computer lights work intermittently 4 1 Check whether the fan is running normally to make it dirty 4 2 Check whether the internal temperature control switch...

Page 7: ...amps and lanterns for repair or before maintenance work that make sure the power is disconnected it is important to keep the lamps and lanterns is clean clean clean please regularly not only keep the...

Page 8: ...e all operations 6 Intelligent height 7 For example check all the decoupling error in the reset and give hints 8 Reset calibration zero calibration 9 X axis Y axis color wheel pattern disk 1 Display i...

Page 9: ...button as the first picture then you can see run mode there have three modes to show different effects Such as AUTO WIRE DMX choose the mode you want here and remermber press save 5 How to make color...

Page 10: ...r s Manual Kullanma Klavuzu 6 How to make reset on the display 7 How to set sound mode Press button as the frist picture TEST RUN SOUND 8 How to check beam info Press button as the frist picture OTHER...

Page 11: ...return stop running Using encoder light coupling judging out of step and automat ically correct position DMX address XY The encoder 1 512 16 Guan keep reset open 20 op DMX From the machine status rec...

Page 12: ...ubble time down to minute DMX channel value In the condition of DMX showing all channels of value number thus the child into the interface display as a percentage value and channel value for viewing S...

Page 13: ...ace display please enter the password XXXXXX Specific operation pro cess press the up and down key to choose Numbers a at a time Password input after fully finally press the OK OK key password authent...

Page 14: ...49 Color 5 Color 6 50 54 Color 6 0 255 1 color tray Options Channel Settings Bright time reset NO YES Screen saver mode Can be set up channel switch Pattern 1 According to address code Pattern 2 Acco...

Page 15: ...stroboscopic mode 3 from slow to fast 192 251 stroboscopic mode 4 from slow to fast 252 255 light 0 19 Closed light 20 255 dimming 0 100 0 53 Change of pattern 54 69 pattern forward running water from...

Page 16: ...fect Prism 0 127 128 255 No prism Prism No prism Prism 000 064 065 127 128 191 192 255 5 6 7 8 9 10 11 12 13 14 15 16 Prism rotation Atomization 0 255 Soft Light Atomizing Effect Pattern clarity from...

Page 17: ...Flow Forward 150 203 Flow Forward 0 103 104 107 108 207 208 212 213 251 252 255 0 4 5 9 10 14 15 19 20 24 25 29 30 34 35 39 40 44 45 49 50 54 55 59 60 64 65 69 70 74 75 79 80 84 85 89 0 4 5 9 10 14 1...

Page 18: ...rd 175 214 Flow Reverse 215 255 Prism Prism auto biography Prism PrismRot Frost Rainbow Focus Pan Tilt PT Speed Macro Lamp Reset Atomization Colorful XY speed Macro functions Focus X axis Y axis Blist...

Page 19: ...19 BEAM 7R 230W BEAM User s Manual Kullanma Klavuzu www qube lighting com www qube lighting com THANK YOU FOR CHOSING QUBE LIGHTING FOR MORE INFORMATION PLEASE...