4

5

This device prevents any wastewater from the 

drain from reverse migration into the tap sys-

tem. It will be required by law in most countries.

INSTALLING QUATREAU SMART TAP™

INSTALLING AIRGAP DRAIN

SECTION THREE

INSTALLING THE TYPE AA 

(AIR GAP) DRAIN

Your kitchen design will, of course, dictate 

where you can install it safely.

4. The standalone tap should be sited on the 

right-hand side of the sink with the spout far-

thest away (at the back) from the user or to the 

back of the sink in a front-to-back orientation. 

Before you start cutting, ensure that you have 

set up a jig or a template device to prevent the 

drill bit from moving when you cut.

If you purchased a stand-alone SmartTap™, 

(unless special order), the icons will be orien-

tated to sit on the right-hand side of the sink 

with the spout facing to the left over the sink. 

The spout will be to the back of the control 

panel.

6. Once the hole(s) is prepared, remove any 

rough edges or bits of wood and place the tap 

carefully into the hole, ensuring that the comms 

cable is dropped into the hole first to prevent 

damage.

8. Using the fixing nut (and washer if required) 

provided, gently tighten to the underside of the 

worksurface to prevent the tap base (or drip 

tray) from moving. Once secure, remove any 

excess silicone using a wet finger to run around 

the edges pushing into the corners to create a 

smooth finish. If the drainer appears to be lifting 

on one side use a weight to hold it down while 

the silicon sets.

1. Open the drain-off kit and type AA air gap 

found in the installation kit. Be careful not to 

lose any parts. Locate a suitable position on 

the approved sanitary drain where the saddle 

clamp can be fixed and ensure that the check 

valve, elbow and air-gap device can sit vertical-

ly without obstruction.

2. Place the saddle valve in a position to allow 

proper gravity fall from the faucet through the 

air gap into the saddle valve.

3. Fix in place and connect the elbow, check-

valve, and finally, the AA airgap fitting and check 

it fits. The top of the AA airgap should be at 

least 6”(152.4mm) below the work surface to 

ensure a gravity fall when connected to the 

VenturiT™ onto the SmartTap™ boiling pipe. 

4-6”(101-152mm) below the work surface (this 

comes later).

4. When you are happy, the parts all fit, and the 

air gap fitting is fixed, pointing directly upward. 

Remove components and use the piercing 

blade or a drill to cut through the waste pipe. 

This part connects to the internal thread on the 

saddle clamp. Once cut, remove this cutting de-

vice completely and discard it.

7. Run a bead of silicone around the edge of 

the holes or around the edge of the tap base 

unit and carefully place the SmartTap™ into the 

worksurface ensuring that the comms cable is 

hanging free underneath the worksurface.

5. If installing the integrated drip tray (QST-D), 

locate it in the center of the worktop with con-

trols to the right-hand side.

THE COMMS CABLE 

CONNECTS INTO THE 

BACK-LEFT SIDE OF 

THE QST553-B. THE 

QST553 MUST BE 

LOCATED CLOSE TO 

THIS CABLE WITH-

OUT CAUSING IT TO 

STRETCH.

5. Now assemble the drain-off kit with the el-

bow, check valve, and AA fitting tightening all the 

collars to create a firm fix. The check valve and 

the airgap creates two (2) different forms of 

backflow prevention.

  

Summary of Contents for SMARTTAP 553-B

Page 1: ...INSTALLATION MANUAL BOILING CHILLED SPARKLING 220V 50Hz...

Page 2: ...LIST 2 UNPACKING YOUR EQUIPMENT 3 INSTALLING QUATREAU SMARTTAP 3 4 INSTALLING AIRGAP DRAIN 5 INSTALLING VENTILATION CHILLER UNIT 6 CONNECTING WATER SUPPLY 7 8 INSTALLING CHILLER CARBONATOR 9 TECHNICAL...

Page 3: ...the Quatreau SmartTap to inspect the components and installation kit Use the packaging to prevent damage until ready to fit the work surface The heater control unit always sits to the right hand side...

Page 4: ...nd in the installation kit Be careful not to lose any parts Locate a suitable position on the approved sanitary drain where the saddle clamp can be fixed and ensure that the check valve elbow and air...

Page 5: ...tallation kit to this 6 35mm connec tion on the mains supply push in firmly then cut it at a length that extends to the front of the cupboard where the water heater inlet will sit 3 In the fitting kit...

Page 6: ...NOTE Ensure that you leave a 1 25 4mm gap around the chiller unit s sides enabling ven tilation and air movement without which the system will not chill correctly DO NOT TURN ON THE POWER TO THE CHILL...

Page 7: ...crew the filter at tached inside by unscrewing the plastic rim 5 Refit the housing to the system and activate the water supply 6 Run the water through chilled then the spar kling then the boiling in t...

Page 8: ...tight the stain less steel housing 12 The optimum contact time for chlorine or sterilizing fluid is 15 minutes before flushing through 13 When ready turn off the water supply back on and run off a few...

Reviews: