background image

2

3

NOTE: 

THE TAP MUST BE SIT-

ED ABOVE OR ADJACENT TO THE 

QST553-B (BOILER CONTROL UNIT), 

CLOSE ENOUGH SO THAT THE COM-

MUNICATION CABLE FROM THE 

SMARTTAP™ IS NOT STRETCHED 

WHEN IT PLUGS INTO THE BACK LEFT 

SIDE OF THE BOILER.

2. 

Cold Water Supply:

 Make sure you install 

an isolation valve on the cold water supply to 

ensure serviceability in the future. 

Minimum 

recommended operating pressure 3bar/45p-

si. Max recommended operating pressure 

4bar/60psi.

3. 

Approved Sanitary Drain:

 Ideally located 

under the sink (see Fig 2.1), unless QSTD will be 

installed with 

INTEGRATED DRIP-TRAY 

(see 

Fig 2.2) drain system will vary. 

An approved type AA fitting (air gap) must be 

used for the venturi waste. Either a trapped up-

stand or drain clamp can be used, or equivalent 

connection approved in the country or state 

of installation. Fittings are provided and can be 

used if applicable for your installation.

4. 

Power: 

The system requires two (2) dedicat-

ed 220V/13 amp circuits to run your Quatreau. 

1. Tools required:  

    a. 

Jigsaw

 - to cut ventilation under chiller   

        into the cupboard base.

    b. 

Drill and bits

 suited to the work surface

    c. SmartTap™ 1 x 30mm core bit  

 

 

        

(or closest match)

        d.  SmartTap™  with  Drain  1x  150mm  core                       

        bit 

(or closest match)

 * 30mm core bit for  

        the buttons. 

1. Your systems have been carefully packaged.

If the box is damaged upon delivery, 

you 

should photograph the damage and remove 

the contents for inspection before signing the 

delivery note.

There will be 2 or 3 boxes depending on the 

model you have purchased.

 

a. Quatreau SmartTap™ (faucet)

 

b. Quatreau Water Heater

 

c. Quatreau Chiller / Chiller Carbonator

2. Open and inspect the Quatreau SmartTap™ 

to inspect the components and installation kit. 

Use the packaging to prevent damage until 

ready to fit the work surface.

The heater control unit always sits to the 

right-hand side of the cupboard with the 

chiller on the left.

 

Cut down each side of the box to reveal the 

systems so that you don’t have to lift them out 

of the box. Install the water heater on the right-

hand side of the cupboard after you’ve installed 

the SmartTap™.

This item weighs 44lbs (19.95kg) Please take 

care when moving or lifting. The sides and 

corners are hard and will damage furniture if 

knocked.

Leave the system on the protective packaging 

until ready to install.

Please open and inspect the chiller carbonator,  

then leave it in its base until ready to install.

1. The Quatreau SmartTap™ will come as a 

stand-alone tap or integrated into a drip-tray. 

With the relevant cutting template enclosed 

with your product, choose the most suitable 

position for the tap.

2. Depending upon the surface, you will need 

special cutting equipment. It is required to use 

a diamond-tipped core bit for granite or mar-

ble. For wood or MDF or polymer type surface, 

a wood bit will normally be adequate. Always 

check with the worksurface manufacturer and 

ask what type of bit can be used.

3. Decide where the tap is going to sit. Note that 

the control panel on the drip tray is on the right-

hand side of the tap. Ensure that the location 

you choose is suitable and that you can reach 

the controls without needing to stretch while 

ensuring that the user will not have to reach 

through the stream of water to operate the 

tap. 

QUATREAU SMARTTAP™

PRE-INSTALLATION CHECK

SECTION ONE

UNPACKING YOUR EQUIPMENT

PRE-INSTALLATION CHECKLIST

UNPACKING YOUR EQUIPMENT

FRAGILE

FRAGILE

1

FRAGILE

2

SECTION TWO

INSTALLING THE QUATREAU 

SMARTTAP™

Summary of Contents for SMARTTAP 553-B

Page 1: ...INSTALLATION MANUAL BOILING CHILLED SPARKLING 220V 50Hz...

Page 2: ...LIST 2 UNPACKING YOUR EQUIPMENT 3 INSTALLING QUATREAU SMARTTAP 3 4 INSTALLING AIRGAP DRAIN 5 INSTALLING VENTILATION CHILLER UNIT 6 CONNECTING WATER SUPPLY 7 8 INSTALLING CHILLER CARBONATOR 9 TECHNICAL...

Page 3: ...the Quatreau SmartTap to inspect the components and installation kit Use the packaging to prevent damage until ready to fit the work surface The heater control unit always sits to the right hand side...

Page 4: ...nd in the installation kit Be careful not to lose any parts Locate a suitable position on the approved sanitary drain where the saddle clamp can be fixed and ensure that the check valve elbow and air...

Page 5: ...tallation kit to this 6 35mm connec tion on the mains supply push in firmly then cut it at a length that extends to the front of the cupboard where the water heater inlet will sit 3 In the fitting kit...

Page 6: ...NOTE Ensure that you leave a 1 25 4mm gap around the chiller unit s sides enabling ven tilation and air movement without which the system will not chill correctly DO NOT TURN ON THE POWER TO THE CHILL...

Page 7: ...crew the filter at tached inside by unscrewing the plastic rim 5 Refit the housing to the system and activate the water supply 6 Run the water through chilled then the spar kling then the boiling in t...

Page 8: ...tight the stain less steel housing 12 The optimum contact time for chlorine or sterilizing fluid is 15 minutes before flushing through 13 When ready turn off the water supply back on and run off a few...

Reviews: