Summary of Contents for INSTANT MATCH SDS263T

Page 1: ...be used with the following Mira Advance Shower Mira Advance Flex Extra 8 7kw 1 1785 005 J09N Installation guidelines for Models SDP134T Whale INSTANT MATCH with Bluetooth wireless technology Kit 300 000 WHALE KITS INSTALLED IN THE UK Please leave this booklet with the end user after installation and demonstration 181 604 IMATCH qxp_Layout 1 14 10 2019 11 24 Page 1 ...

Page 2: ... and the condition of the internal rubber components For video assistance on how to check the pipework for issues and for a video instructing you how to inspect and change the pump components please visit www whalepumps com psd If your pump doesn t turn on First check the power is on at the fused spur If on please contact an electrician to inspect the power to the pump or contact our Technical Hel...

Page 3: ...the ability to run dry without causing damage Non return valves in the pump head prevent smells entering the bathroom area from the waste pipe Installation Warnings Before installation please read the instructions All electrical and mechanical components transformer and pump must be accessible after installation The Whale Instant Match with Bluetooth wireless technology is designed to work on show...

Page 4: ...p 12 Bluetooth wireless technology unpairing 15 Hardwired setup 16 Purge cycle 18 Swapping pump transformer on backplate 18 Safety warning 18 Installation testing and repair 19 EU declaration of conformity 20 Statement of limited warranty 20 Specification 21 List of parts included in the kit 22 Spare and Accessories 22 Fault diagnosis 24 25 Product dimensions 26 27 Index 4 181 604 IMATCH qxp_Layou...

Page 5: ...m for 22mm inlet pipe for mixer showers Pump and Flow Sensors MUST BE ACCESSIBLE AFTER INSTALLATION Use slow radius bends where possible Full size elbows are acceptable not stem or Male Female elbows Where possible avoid attaching elbows directly to the pump Inserts MUST NOT be used with plastic pipe Please use the push fit fittings supplied with the kit Ensure the pipe is pushed fully home into t...

Page 6: ...re a floor former is not used the gulley has two lugs either side of the discharge pipe to enable the gulley to be fixed to the floor whilst screed is laid Where a floor former is used these lugs can be easily broken off to enable it to be fitted The gulley has a conventional clamping ring to accommodate vinyl flooring Once the area has been cleaned and before the shower is lined remove dust seal ...

Page 7: ... Fig 1 5 for 32mm 1 1 4 McAlpine examples and the McAlpine catalogue for other variants Use with a Macerator Pump Discharge from the Whale pump must go into the top of the macerator box Do not use the bottom entries See Fig 1 6 It is preferable to have two separate discharge lines to waste as any failure of the macerator will not be detected by the Whale pump Fig 1 6 Fig 1 5 22mm V33T 32mm 1 1 4 A...

Page 8: ... pump outlet to discharge into the waste pipe The pump head may be rotated to the left hand side or right hand side Mount square to wall Using a spirit level ensure that the unit is mounted level Do not install the pump inlet outlet more than 500mm off the floor NOTE The pump and transformer mounting location on the backplate may be swapped right to left left to right See Page 18 for further infor...

Page 9: ...ckplate to the wall using supplied screws Use screw locations 1 2 3 Locations A and B are optional 3 Mounting your pump to the wall Push the pipes into the fittings to the full depth of insertion and secure by locking the fittings using the twist lock 4 Plumbing connections 9 B A 181 604 IMATCH qxp_Layout 1 14 10 2019 11 24 Page 9 ...

Page 10: ...en the screws to make the transformer water resistant 5 Wiring your transformer The blue LED flashes every 10 seconds indicating that power is on The green LED flashes when water is flowing through the shower When the test button is depressed the buzzer beeps 6 The Whale Instant Match with Bluetooth wireless technology transformer includes Activelink diagnostics to aid installation On the transfor...

Page 11: ...only 2ᴓ 22mm inlet pipe for mixer showers 8 Optional external pump overrun switch Use a retractive switch to briefly activate the pump This facility is for use when the wet area is being cleaned or for ritual cleansing The pump will run for 15 seconds at full speed to clear any water in the showering area The retractive switch shown is available from Screwfix Retractive Switch 1 Gang 1 Way Part No...

Page 12: ...e to operate within the same room The Bluetooth connection is only to be used where the transformer is installed in the bathroom with the shower Where the transformer is installed in a boxing only plastic access panels are to be used Hardwired connections should be used where the transformer is mounted outside of the bathroom area If any components or cords are damaged it must be replaced by a qua...

Page 13: ... not yet been established Press and hold the blue test button on the transformer until the the light flashes red and green to indicate that the transformer is now in pairing mode NOTE You now have 120 seconds to pair the transformer to the shower 13 Turn on power to the shower using the pull cord This will automatically pair the shower and pump 3 Configuring the shower 181 604 IMATCH qxp_Layout 1 ...

Page 14: ...wer please follow these steps 1 Switch the mains electric supply to the shower OFF 2 Be sure to leave the mains electric supply to the pump ON The light on the transformer will flash blue Plumbing of the Waste Pipe Bluetooth wireless technology unpairing 3 Press and hold the test button on the transformer until the light flashes red The transformer and shower have now been unpaired NOTE To pair th...

Page 15: ...nd shower Isolate power from Mira shower Remove front cover from Mira shower Move DIP switch BLE PUMP ENABLE to OFF position See opposite 2 Power cycle shower Replace front cover Turn power on to Mira shower 3 Pair transformer and shower Isolate power from Mira shower Remove front cover from Mira shower Move DIP switch BLE PUMP ENABLE to ON position See opposite Replace front cover The shower is r...

Page 16: ...side signal block as shown Red Brown Black Ensure that that your transformer is set to be used with a hardwire connection the flow sensor setting should be set to 6 for Mira Wired and the pipe inlet diameter should be set to 1 for 15mm Set up The Whale Instant Match transformer SDS236T can be connected to the Mira Advanced Flex Extra J09N shower by means of a hard wired connection 16 1 2 3 4 5 6 7...

Page 17: ...perate correctly when using the listed transformer Connect the signal cable from the 755 678 transformer to the shower working from left to right as shown Brown Red and Black Switch the mains electric supply to the transformer and shower on The pump will now operate when the shower is activated Drain Pump Type 755 199 755 210 755 299 755 349 755 399 755 449 755 549 Shower Advance Control PCB LK1 O...

Page 18: ...e the pump for 30 seconds at a lower flow rate to remove any run off or condensation that has collected in the gulley to leave the shower area dry Swapping the mounting location of the pump and transformer on the backplate Unscrew pump from base Remove the transformer from its secure mounting by pressing the securing tab on bottom of transformer Move transformer to opposite side of the casing and ...

Page 19: ...ting the floor tray See Fig 1 7 FLOW RATE TESTING A convenient way to measure the flow rate is to get a 2ltr plastic jug and mark the 2ltr level in black pen Turn the shower on to where the customer normally uses it often maximum setting Put the jug under the shower head and measure how long it takes for the jug to fill to the 2ltr line Longer than 20 seconds indicates flow rate of less than 6ltrs...

Page 20: ...the Company notice of any Defect or the Buyer alters or repairs such Products without the written consent of the Company Products that have been disassembled or modified without prior written approval of the Company are not covered by this warranty All Products are covered by a 3 year limited warranty detailed below from unless otherwise extended in advance in writing by the Company date of purcha...

Page 21: ...r for any indirect or consequential loss or damage whether for loss of profit loss of business depletion of goodwill or otherwise costs expenses or other claims for consequential compensation whatsoever howsoever caused which arise out of or in connection with the use of a Product Where dimensions are stated such dimensions are for guidance only Inch measurements are conversions from millimetre di...

Page 22: ...aste adapter 2 parts 22mm 1 fitting 1 22mm 22mm fitting 1 Spares andAccessories These additional parts may be ordered from your distributor Description Part No 90mm Gulley AK1695 Sika flow sensor SDS263T Shower Drain Pump SDS021T Instant Match Bluetooth Transformer SDS236T Tricuspid Valve Qty 10 SDS211B Pump head replacement kit SDS071T Diaphragm and Tricuspid kit SDS061T 10 ltrs per min flow regu...

Page 23: ...andoffs Where pipe runs make installation of the pump base difficult we recommend the use of a Space Plug Available from SCREWFIX Version 30 50mm shown below 23 181 604 IMATCH qxp_Layout 1 14 10 2019 11 24 Page 23 ...

Page 24: ... the TEST button on top of the transformer Does the buzzer beep NO YES NO NO YES YES NO The transformer allows the pump to over run for up to 60 seconds If the pump continues to run after this time has elapsed switch off the transformer at the mains and allow it to cool and re set If this does not solve the problem replace transformer SDS236T 755 678 WIRED Check transformer setting is correct for ...

Page 25: ...OK remove and inspect the pump head as described in the Installation Repair section of these instructions Take care to confirm that flap valves close properly and that the diaphragm bead has not been squashed These parts are available in the Replacement Head Kit SDS071T includes diaphragm and tricuspid or Replacement Diaphragm and Tricuspid Kit SDS061T Check for blockages on inlet and outlet pipe ...

Page 26: ...PE USE ONLY 22MM PIPE ON THE PUMP OUTLET 0 2 M MIN 0 4 M MAX FORMED BEND 1M MAX WASTE PIPE HORIZONTAL TO WASTE PIPE TO INCREASE PUMP LIFE ENSURE THAT 32mm 1 1 4 or 40mm 1 1 2 PIPE IS USED WITH A GRAVITY FALL WHERE THE PIPE LENGTH IS GREATER THAN 1M IF LESS THAN 1M USE 22MM PIPE WARNING WARNING 0 5 M MAX Fig 1 1 26 For mixer showers 22mm pipe work is required Max run to pump is 2 mtrs from the gull...

Page 27: ...Pump SDS021T 255mm 310mm Contact the Technical Helpline If you need further assistance 0345 9090 912 27 TRICUSPID VALVE 127mm 181 604 IMATCH qxp_Layout 1 14 10 2019 11 24 Page 27 ...

Page 28: ...5 9090 912 drainagesupport whalepumps com www whalepumps com psd Whalecare Whale 2 Enterprise Road Bangor Co Down BT19 7TA N Ireland ref 181 604_v5_1019 181 604 IMATCH qxp_Layout 1 14 10 2019 11 24 Page 28 ...