Rack-Mount RDMS
TM
Telemetry Receiver
140
Quasonix, Inc.
Mnemonic
Name
Description
Option (s)
Required
Command
Level
Mode
Restriction
OM
Output Muting
Report or set the operation of
clock and data output
muting; clock and data
outputs can be disabled after
some period of time without
lock
Examples:
OM
Show the output
muting state
OM 0 Disables output
muting
OM 1 Enables output
muting
OM T x Sets the delay
between loss of lock and
muted outputs in
milliseconds from 0 to 46016
Standard
Advanced
Command
None
PA
Reset Stored
Configuration
Resets all parameters in all
waveform modes to the
factory default state
Refer to Appendix D for
default values by mode
Standard
Basic
None
PL
Input Power
Level
Reports or sets the current
input power level setting
Examples:
PL
Report the current
input power level information
tracking state
PL 0
Set the current
power level information
tracking display to Off
PL 1
Set the current
power level information
tracking display to On
Standard
Advanced
Command
None
PL A
Power Level
Automatic
Control Mode
Sets power level automatic
control mode
Examples:
PL A 0 Set the power level
automatic control mode to
Software
PL A 1 Set the power level
automatic control mode to
Hardware
Standard
Advanced
Command
None