Rack-Mount RDMS
TM
Telemetry Receiver
138
Quasonix, Inc.
Mnemonic
Name
Description
Option (s)
Required
Command
Level
Mode
Restriction
MA
Modulations
Allowed
Report the available
waveform modes
(modulations) available for
this unit
Standard
Basic
None
MI
Modulation
Index
Report or Set Modulation
Index Tracking or Acquire
Examples
MI Report Mod Index
Track Status
MI O Disable Mod Index
Tracking (Set to h=0.7)
MI A Acquire mode enable
MI A D Sets the maximum
delta h (indicates a change in
h defaults to 0.005)
MI A S Sets the delta h
settling time defaults to 500
ms
MI H Hold Mod Index
Tracking at current position
MI I Sets Trellis Index
MI T Tracking mode
enable
MI T H x Sets the Tracking
Hold threshold
Standard
Basic
PCM/FM