Quark-elec Manual
https://www.quark-elec.com
10 of 28
2018
V3
8. Alarm function connections
G031 has two external alarm input connectors and various inputs can be connected to them. For
example, door/windows sensors, smoke alarms, carbon dioxide detectors, motion sensors, thermostats,
temperature/wind detectors, and moisture detectors.
Using these sensors/detectors, G031 can be setup as a protection/alarm and response system.
Alarm input port
Corresponding relay number
External alarm 1 (INT1)
Relay 1
External alarm 2 (INT2)
Relay 2
There are two typical ways the external alarm inputs can communicate with G031. External alarm devices
can be used as,
1. Switch
2. Alarm input source (low level voltage signal)
G031 external alarm inputs are active when a trigger pulse or a constant level of 0.0V is applied.
If the sensor/detectors are triggered (low level signal (0.0V) to G031); G031 will send out an SMS to the
registered mobile terminals. Meanwhile, the corresponding relays setup will be activated.
To disable the external alarm input
, text '
EXTGBn
' (replace ‘n’ with the relay number).
To enable all external alarm inputs
, text '
EXTRT
'.