All safety related codifications, symbols and instructions that appear in this operating manual
or on the equipment must be strictly followed to ensure the safety of the operating personnel as
well as the instrument.
If all the equipment is not handled in a manner specified by the manufacturer, it might impair the
protection provided by the equipment .
Product improvement and upgrade is a constant procedure. So for more updated operating information and support,
Please contact our helpline : +91-9978991474/76/82 or Email at [email protected] Ver: 01-2017
=>
Read complete instructions prior to installation and operation of the unit.
WARNING
: Risk of electric shock.
3) Cable used for connection to power source, must have a cross section of 1mm or greater. These wires
should have insulations capacity made of at least 1.5kV.
2) To reduce electro magnetic interference, use wire with adequate rating and twists of the same of equal size shall
be made with shortest connection.
4) When extending the thermocouple lead wires, always use thermocouple compensation wires for wiring for the RTD
type, use a wiring material with a small lead resistance (5
Ω
max per line)and no resistance differentials among
three wires should be present.
1) To prevent the risk of electric shock power supply to the equipment must be kept OFF while doing the wiring
arrangement. Do not touch the terminals while power is being supplied.
5) A better anti-noise effect can be expected by using standard power supply cable for the instrument.
1) This equipment, being built-in-type, normally becomes a part of main control panel and such in case the
terminals do not remain accessible to the end user after installation and internal wiring.
2) Do not allow pieces of metal, wire clippings, or fine metallic fillings from installation to enter the product
or else it may lead to a safety hazard that may in turn endanger life or cause electrical shock to the operator.
3) Circuit breaker or mains switch must be installed between power source and supply terminal to
facilitate power ‘ON’ or ‘OFF’ function. However this mains switch or circuit breaker must be
installed at convenient place normally accessible to the operator.
4) Use and store the instrument within the specified ambient temperature and humidity ranges as
mentioned in this manual.
Warning Guidelines
Safety Precautions
Installation Guidelines
Mechanical Installation
Maintenance
1) Prepare the panel cutout with proper dimensions as show above.
2) Fit the unit into the panel with the help of clamp given.
3) The equipment in its installed state must not come in close proximity to any heating source,
caustic vapors, oils steam, or other unwanted process by products.
4) Use the specified size of crimp terminal (M3.5 screws) to wire the terminal block. Tightening the
screws on the terminal block using the tightening torque of the range of 1.2 N.m.
5) Do not connect anything to unused terminals.
1) The equipment should be cleaned regularly to avoid blockage of ventilating parts.
2) Clean the equipment with a clean soft cloth. Do not use isopropyl alcohol or any other cleaning agent.
3) Fusible resistor must not be replaced by operator.
2
UTC-113P,213P,413P
95mm - 3.75 inches
85mm - 3.34 inches
68mm - 2.68 inches
60mm - 2.36 inches
136mm - 5.35 inches
120mm - 4.72 inches
B
A
C
C
C
D
D
D
F
E
F
E
MODEL
A
96mm
96mm
92mm
92mm
3mm
50mm
B
C
D
E
F
DIMENSIONS
MODEL
A
72mm
72mm
68mm
68mm
3mm
85mm
B
C
D
E
F
DIMENSIONS
MODEL
A
48mm
48mm
44mm
44mm
3mm
95mm
B
C
D
E
F
DIMENSIONS
B
A
1 2 3
UTC 413P
UTC 113P
R
PV
ºC
1 2 3
B
A
R
PV
TUNE
SET
ºC
UTC 213P
1 2 3
E
F
TC
+
-
+
SSR
O/P
RTD
6
7
8
9
10
-
1
2
3
4
5
NC
C
R1
NO
L
!
100
250V AC
50/60 HZ
4VA
~
!
100
270V AC
50/60 Hz
4VA
~
TC
+
RTD
-
!
L
N
1
2
3
4
5
6
7
-
+
O/P
S.S.R
RELAY1
100
270V AC
~
50/60 Hz
4VA
NC
NO
C
8
9
10
11
12
13
14
1
7
8
9
12
13
14
10
11
16
17
18
19
20
15
2
3
4
5
6
NC
C
NO
TC
+
-
+
-
RELAY
100
270V AC
~
50/60 Hz
4VA
!
L
N
O/P
S.S.R
RTD
www.multispanindia.com
Page - 1
UTC-113P,213P,413P
Note:
1)
If Sensor Connection is reversed, Display will show “
SRE
” message.
2) If Sensor is not connected, Display will show
Opn
message.
3) Every time the instrument is turned ON, Following pattern will be displayed
J: 0 to 600°C / K: 0 to 999°C /
PT-100: -99 to 400ºC
PID / ON-OFF (selectable)
Output
Power Supply
Protection Level
Operating
Relative
(As per request)
Temperature
Humidity
1 relay, 1 C/O contact, 230V AC, 5A ; 1 SSR,12V DC Approx, 30mA DC
100 to 270V AC, 50 / 60 Hz, Approx 4VA
IP-65(Front side) AS per IS/IEC 60529:2001
0°C To 55°C
Up to 95% RH Non Condensing
Model
Display
Size(HXWXD)
Panel Cutout
Input
Temperature
Range
Control Action
UTC 113P
96 X 96 X 50 mm
68 X 68 mm
92 X 92 mm
44 X 44 mm
72 X 72 X 85 mm
48 X 48 X 95 mm
3 Digit 7 seg 0.56”,red LED Display
UTC 213P
UTC 413P
J, K, PT-100 (selectable)
Technical Specification
Connection Diagram
OPERATING MANUAL
PID TEMPERATURE CONTROLLER
UTC-113P, 213P & 413P
1 2 3
UTC 413P
POWER ON
All digit segment will be turned ON for 3 sec
Previous or default sensor input will be display for 2 sec
Process Value
8 8
8
- J -
1 2 3
UTC 113P
R
PV
ºC
1 2 3
R
PV
TUNE
SET
ºC
UTC 213P
1 2 3
N
Made in India
www.multispanindia.com
Made in India
www.multispanindia.com
Made in India
www.multispanindia.com