StorNext QS1200 / QS2400, Replacing a Host Interface Card (HIC)

April 2015

Quantum Corporation

- 10 -

5.

Look at the Controller Service Action Required LED, and look at all of the base system’s Service Action Required 
LEDs. Based on the LED status, perform one of these actions:

All of the Service Action Required LEDs are off, 

and

 the Array Management Window indicates an 

Optimal status

 – Go to step 

7

.

Any of the base system’s Service Action Required LEDs are on, 

or 

the Controller Service Action 

Required LED is on 

– Check that the controller canister has been installed correctly. Reinstall the controller 

canister, if necessary. Go to step 

6

.

6.

Did this action correct the problem?

Yes

 – Go to step 

7

.

No

 – If the problem is not resolved, contact your Technical Support representative.

7.

Using the LEDs and the storage management software, check the status of all of the base systems in the storage 
array.

8.

Does any component have a 

Needs Attention 

status?

Yes

 – Click the 

Recovery Guru

 toolbar button in the 

Array Management 

Window, and complete the 

recovery procedure. If the problem is not resolved, contact your Technical Support representative.

No

 – Go to step 

9

.

9.

Remove the antistatic protection.

10. Gather support data about your updated storage array by using one of these methods:

Use the storage management software to collect and save a support bundle of your storage array. From the 

Array Management Window

 toolbar, click 

Monitor > Health > Collect Support Data

. Then name and 

specify a location on your system where you want to store the support bundle.

Use the CLI to run the 

save storageArray supportData

 command to gather comprehensive support 

data about the storage array. For more information about this command, see the 

Command Line Interface and 

Script Commands

 document. Running this command can temporarily impact performance on your storage 

array.

Summary of Contents for StorNext QS1200

Page 1: ...StorNext QS1200 QS2400 Replacing a Host Interface Card HIC 6 68079 01 Rev B 6 68079 01 B...

Page 2: ...NT Quantum the Quantum Logo Backup Recovery Archive It s What We Do Be Certain Be Quantum Certain DLT the DLT Logo DLTSage DLTtape the DLTtape Logo DXi DXi Accent Dynamic Powerdown FastSense FlexLink...

Page 3: ...ore you replace an HIC gather antistatic protection a new HIC and the controller air blocker If you are changing your current configuration you might need to replace these items in addition to the HIC...

Page 4: ...ance on your storage array 2 Did the Recovery Guru direct you to replace a failed I O host interface card Yes Go to step 3 No Run the Recovery Guru to identify the failed component and go to step 3 3...

Page 5: ...l Guide Use either the GUI first bullet or the CLI second bullet to take the appropriate controller offline From the Hardware pane in the Array Management Window right click the picture of the control...

Page 6: ...n Required LED Amber 3 Disconnect all cables from the controller canister that contains the HIC If the storage array is running while you perform this replacement do not disturb the second controller...

Page 7: ...angles so it is ready to insert into the open controller slot Figure 4 Controller Air Blocker 5 Remove the controller canister Figure 5 a Unlock and pull out the release levers to release the control...

Page 8: ...because of the possibility of overheating the equipment The controller air blocker fills the controller slot so that the equipment will not overheat 7 Insert the controller air blocker into the open...

Page 9: ...Remove the top cover Figure 7 Host Interface Card Replacement 1 Top Cover Latch Buttons 2 HIC Thumbscrews 3 Host Interface Card 4 HIC Interface Connector 5 Front Bezel 6 Zero Insertion Force ZIF Sock...

Page 10: ...harness or the ZIF socket that is attached to the controller card Make sure that you gently move the front bezel away from the controller canister to allow access to the HIC NOTE If the thumbscrews w...

Page 11: ...P address c set controller a b availability online 4 Look at the LEDs on the controller canister Figure 8 to make sure that the controller is rebooting correctly The seven segment display shows the se...

Page 12: ...check the status of all of the base systems in the storage array 8 Does any component have a Needs Attention status Yes Click the Recovery Guru toolbar button in the Array Management Window and compl...

Reviews: