Quantum PX720 Unpacking and Installation Instructions
Document 6444602-04 A01
March 2005
Installing the Quantum PX720 Library
29
4
The SCSI, Ethernet, and Fibre Channel cables must be routed and stacked
in the right-hand clamps correctly so the back door will close. Route the
cables down through the cable channel on the right-hand side of the
library. Refer to
figure 29
and
figure 30
for cable diagrams illustrating the
correct cable placement.
Table 2 Cabling a FC470
Bridge to the Tape Drives
Caution:
Use care when handling the fibre optic cables. Do not
crimp or bend the cables.
Tape Drive Connection
FC470 Connections/ Tape Drive
Termination
Tape drive 0, upper port
Port 0 on first FC470
Tape drive 0, lower port
Library SCSI HBA
Tape drive 1, upper port
Port 1 on first FC470
Tape drive 1, lower port
Terminator
Tape drive 2, upper port
Port 2 on first FC470
Tape drive 2, lower port
Terminator
Tape drive 3, upper port
Port 3 on first FC470
Tape drive 3, lower port
Terminator
Tape drive 4, upper port
Port 0 on second FC470
Tape drive 4, lower port
Terminator
Tape drive 5, upper port
Port 1 on second FC470
Tape drive 5, lower port
Terminator
Tape drive 6, upper port
Port 2 on second FC470
Tape drive 6, lower port
Terminator
Tape drive 7, upper port
Port 3 on second FC470
Tape drive 7, lower port
Terminator
Tape drive 8, upper port
Port 0 on third FC470
Tape drive 8, lower port
Terminator
Tape drive 9, upper port
Port 1 on third FC470
Tape drive 9, lower port
Terminator