![Quantum Harvest 3000-60 TSW Owner'S Manual Download Page 31](http://html1.mh-extra.com/html/quantum/harvest-3000-60-tsw/harvest-3000-60-tsw_owners-manual_3505580031.webp)
Section 6C:
Soft-start Module removal/replacement
Tools needed: #2 Phillips screwdriver
Step 1:
Remove the power board. (Pages 21-22)
Step 2:
Remove the batteries. (Pages 23-24)
Step 3:
Below,
Disconnect the 2 cords (red circle), and the 2-pin connector, (green circle).
Step 3:
Right,
Remove the 4 screws
on the hinge-side of the cabinet, and
remove the soft-start module.
Reverse the above steps to re-install.