Step 3:
Using the handles provided, pick the entire unit up slightly, move it toward the control
panel slightly to clear the inverter power socket, and pull the rear up to clear the back of the
cabinet, and let it rest there at an angle as shown below to allow you to disconnect the 6 cables
that tie the power assembly to the main unit.
350 amp Anderson
Connector
Step 4:
Above,
Disconnect the large gray 350 amp connector by pulling it apart as shown.
(Due to it's robust design, it takes a fair amount of effort to disconnect it. It helps to rock one
segment from side to side while pulling it apart.)
Step 5:
Below
, Disconnect the 4 connectors detailed below.
Charge Controller to Battery Bank
Connector (yellow)
Solar Panel to Charge Controller
Connector (black)
AC Charger to Battery Bank Connector
(2-pin)
AC Charger to Input Jack Connector (3-
pin)
It is important to note that the yellow connectors go
together, and the black solar panel to charge controller
connectors go together. Be advised that it is possible to cross
these, and doing so may damage the solar charge controller!
24