Section 2:
Controls/Circuit Protection Devices
There is one main fuse, a 400 ampere ANL type fuse,
shown to the right, located beside the inverter. There is
one spare fuse included in the spare parts kit. To
replace the fuse, first, be sure the main switch is turned
off, then, using a 9/16” wrench, remove the two nuts.
Lift the fuse out and place the new one over the studs;
reapply the nuts, being careful to not over-tighten.
Detail of Main Control Panel
Anderson connector for Voltage/Charging amps meter 220 volt AC
breaker
booster cables 220 volt system on/off switch
Polarity indicator LEDs for use
with the booster cables
(see section 5)
12 Volt DC cigarette
lighter-style outlets
USB charger ports (2) 120 volt AC outlets
Inverter start button 220 volt AC outlet
Main Switch; 4 positions available.
Off
position isolates the inverter and control panel from the batteries.
Position #1
is the normal use position in which the unit draws from the internal battery bank.
Position #1&2
is the position used when using the booster cables, and allows the unit to run
from both the internal battery bank and the vehicle's charging system.
Position #2
is not normally used, and allows the load to be run directly from an automobile's
charging system, bypassing the internal battery bank.
8