DPM5500 Quick Start Guide
3
Locating the Mounting
Position
0
The DPM5500 system is designed to fit in a standard 19 inch
wide rack. It is important to the chassis installation to locate
the hole pattern in the rack rails (see
figure 2
).
Figure 2 Rail Hole Pattern
W
ARNING
:
If the rack is empty at the time of
installation, do NOT install the DPM5500
chassis too high in the rack. The weight of
the chassis may cause the rack to become
“top heavy” and unstable if installed in the
top of an empty rack.
5U of ra
ck sp
ac
e
1 DPM5500 System (5U)
1U = 1.75 in
(44.45mm)
5U
.625 in (15.9 mm)
.625 in (15.9 mm)
.5 in (12.7 mm)
.625 in (15.9 mm)
.625 in (15.9 mm)
Top of rack
.312 in (7.92 mm)
.5 in (12.7 mm)
Hole pattern
The marks above (
X
)
indicate the location of
mounting hardware on
the rack rails. Ensure that
any necessary mounting
hardware is installed on
the rack rails prior to
installing the chassis.
Installing the DPM5500
Chassis
0
1
Assemble the DPM5500 rack rails as shown in
figure 3
.
You must pull the slide out of the support brackets to
gain access to the mounting holes.
Figure 3 Assembling the Rack
Rails
2
Install the left and right rack rails at the beginning of a
hole pattern (see
Locating the Mounting Position
) and
install two 10-32 x .50 PHILLIPS screws on each rail at
the front and back of the rack (see
figure 4
).
N
OTE
:
Quantum ships sufficient clip nuts to support
mounting the DPM5500 rack rails and also to
secure the front of the chassis to the rails.
N
OTE
:
The support brackets extend to accommodate
rack depths or 30 to 36 in. (76.2 to 91 cm).
N
OTE
:
Ensure that clip nuts are installed on the rails (see
figure 2
) prior to installing the DX5000 rails.
Clip nut
DPM5500:
Adjustment
screws; adjusts to the
depth of your rack
DPM5500:
Front mounting
bracket preset. Ensure the
screws are in the correct
position.