Chapter 4 SCSI Commands
INQUIRY Command (12h)
DLT-S4 Interface Reference Guide
49
Sequential-Access Device Capabilities VPD Page (B0h)
4
Figure 16
and
table 26
specify and describe the sequential-access device
capabilities VPD page. This page provides the application client with the
means to determine if the features specified in this page are supported by
the device server.
Figure 16 Sequential-Access
Device Capabilities VPD Page
— Data Format
Table 26 Sequential-Access
Device Capabilities VPD Page
— Field Descriptions
Bit
Byte
7
6
5
4
3
2
1
0
0
Peripheral Qualifier
Peripheral Device Type
1
Page Code (B0h)
2 — 3
(MSB)
Page Length (4)
(LSB)
4
Reserved
WORM (1)
5 — 7
Reserved
Field
Description
Peripheral Qualifier
Contains 000b.
Peripheral Device
Type
Contains 01h.
Page Length
The
PAGE LENGTH
field specifies the length of the following VPD page data. If the
allocation length value in the
INQUIRY
command descriptor block is too small to
transfer all of the VPD page data, the page length is not adjusted to reflect the
truncation.
WORM
The Write Once, Read Many (WORM) bit indicates if the device is capable of
supporting this mode. This bit is always set to 1.