![Quantech QWC3050T-200T Installation Operation & Maintenance Download Page 97](http://html1.mh-extra.com/html/quantech/qwc3050t-200t/qwc3050t-200t_installation-operation-and-maintenance_3559367097.webp)
SECTION 5 – TECHNICAL DATA
FORM QWC3-NM1
ISSUE DATE:11/20/2020
QUANTECH
97
5
SEISMIC ISOLATOR INSTALLATION AND ADJUSTMENT
Units shipped on or after June 15, 2008
1. Read instructions in their entirety before begin-
ning installation.
2. Isolators are shipped fully assembled and are to be
positioned in accordance with the submittal draw-
ings or as otherwise recommended.
3.
Set isolators on floor, housekeeping pad, or sub-
base, ensuring that all isolator centerlines match
the equipment mounting holes. The VMC group
recommends that the isolator base plates (
“
B”) be
installed on a level surface. Shim or grout as re-
quired, leveling all isolator base plates to the same
elevation (1/4-inch maximum difference can be
tolerated).
4. Bolt or anchor all isolators to supporting structure
utilizing base plate thru holes (
“
C”) or weld base
plate to supporting structure with 3/8 fillet weld
2" long @ 4" on center around entire base plate or
as engineered for specific load and or field condi
-
tions.
5. Isolators are shipped to the job site with (2) re-
movable spacer shims (
“
E”) between the top plate
and the housing. These shims must be in place
when the equipment is positioned over the isola-
tors.
6. With all shims (
“
E”) in place, position equipment
on top of plate (
“
A”) of isolator. Bolt equipment
securely to top plate of isolator using a minimum
of (2) 5/8 UNC A325 grade 5 SAE bolts or weld
equipment or bracket to the top plate (
“
A”) of iso-
lator with a minimum of 3/8 fillet welds 2" long @
3" on center for a minimum total weld of 10". (All
sides of equipment or bracket resting on top plate
(
“
A”) must be welded).
7. The adjustment process can only begin after the
equipment or machine is at its full operating
weight.
8.
Back off each of the (4) limit stop lock nuts (
“
F”)
on isolators 1/2".
9. Adjust each isolator in sequence by turning spring
adjusting nuts (
“
G”) one full clockwise turn at a
time. Repeat this procedure on all isolators, one
at a time. Check the limit stop lock nuts (
“
F”) pe-
riodically to ensure that clearance between the
washer and rubber grommet is maintained. Stop
adjustment of isolator only when the top plate
(
“
A”) has risen just above the shim (
“
E”).
10. Remove all spacer shims (
“
E”).
11. Fine adjust isolators to level equipment.
12. Adjust all limit stop lock nuts (
“
F”) per isolator,
maintaining 1/4 of an inch to a 3/8-inch gap. The
limit stop nuts must be kept at this gap to ensure
uniform bolt loading during uplift (as the case
when equipment is drained).
13. Installation is complete.
LD13763B
WASHER
("F")
("B")
GROMMET
("G")
("A")
("C")
("F")
("E")
("E")
("E")
1/4 - 3/8 GAP
CL
CL
("C")
EQUIPMENT
("A")
Summary of Contents for QWC3050T-200T
Page 4: ...FORM QWC3 NM1 ISSUE DATE 11 20 2020 QUANTECH 4 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 10: ...FORM QWC3 NM1 ISSUE DATE 11 20 2020 QUANTECH 10 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 28: ...FORM QWC3 NM1 ISSUE DATE 11 20 2020 QUANTECH 28 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 144: ...FORM QWC3 NM1 ISSUE DATE 11 20 2020 QUANTECH 144 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 152: ...FORM QWC3 NM1 ISSUE DATE 11 20 2020 QUANTECH 152 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 166: ...FORM QWC3 NM1 ISSUE DATE 11 20 2020 QUANTECH 166 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 185: ...FORM QWC3 NM1 ISSUE DATE 11 20 2020 QUANTECH 185 NOTES...