Accessories and Options
All options are factory installed unless otherwise noted.
ELECTRICAL OPTIONS
Single-Point Non-Fused Disconnect Switch
– Unit-mounted disconnect switch with ex-
ternal, lockable handle (in compliance with Article 440-14 of N.E.C.), can be supplied to
isolate the unit power voltage for servicing. Separate external fusing must be supplied,
by others in the power wiring, which must comply with the National Electrical Code and/
or local codes.
Single-Point Circuit Breaker
– A unit mounted circuit breaker with external, lockable
handle (in compliance with N.E.C. Article 440-14), can be supplied to isolate the power
for servicing. (This option includes the Single-Point Power connection.)
Control Transformer
– Converts unit power voltage to 115-1-60 or 115-1-50 if 50hz is
selected (0.5 or 1.0 KVA capacity). factory mounting includes primary and secondary wir-
ing between the transformer and the control panel.
CONTROL OPTIONS
Ambient kit (Low)
– Standard units will operate to 25°f (-4°C). This accessory includes
all necessary components to permit chiller operation to 0°f (-18°C). (This option includes
the discharge Pressure Transducer/readout Capability option.) for proper head pres-
sure control in applications below 25°f (-4°C), where wind gusts may exceed five mph, it
is recommended that optional Condenser louvered Enclosure Panels also be included.
Ambient kit (High)
– required if units are to operate when the ambient temperature is
above 110°f (43°C). includes discharge pressure transducers. (This option includes the
discharge Pressure Transducer/readoutCapability option.) (field-mounted.)
Language LCD And keypad Display
– Spanish, french, and German unit lCd controls
and keypad display available. Standard language is English.
Discharge Pressure Transducers And Readout Capability
– The addition of pressure
transducers allows models to sense and display discharge pressure. This is recommend-
ed for glycol chilling applications. (This option is included with either the low or high ambi-
ent kits.)
Suction Pressure Transducers
– Permits unit to sense and display suction pressure.
This capability is standard.
Motor Current Module
– Capable of monitoring compressor motor current. Provides
extra protection against compressor reverse rotation, phase-loss and phase imbalance.
option consists of one module per electrical system.
COMPRESSOR, PIPING, EVAPORATOR OPTIONS
Low Temperature Glycol
– required for glycol chilling below 30°f (-1°C) leaving glycol
temperature. option includes resized thermal expansion valve.
Chicago Code Relief Valves
– Unit will be provided with relief valves to meet Chicago
code requirements.
Summary of Contents for QTC2015T
Page 4: ...QUANTECH FORM QTC2 eg1 515 4 This Page Intentionally Left Blank...
Page 12: ...QUANTECH FORM QTC2 eg1 515 12 This Page Intentionally Left Blank...
Page 25: ...FORM QTC2 eg1 515 QUANTECH 25 Unit Dimensions English Cont d QTC2025T LD18674...
Page 33: ...FORM QTC2 eg1 515 QUANTECH 33 45 1 8 18 1 2 LD18682 Unit Dimensions English Cont d QTC2045T...
Page 47: ...FORM QTC2 eg1 515 QUANTECH 47 Unit Dimensions Metric Cont d QTC2045T 424 LD18702...
Page 57: ...FORM QTC2 eg1 515 QUANTECH 57 Power Wiring LD18707...
Page 58: ...QUANTECH FORM QTC2 eg1 515 58 LD18744 Power Wiring Cont d...
Page 59: ...FORM QTC2 eg1 515 QUANTECH 59 Power Wiring Cont d LD18746...
Page 60: ...QUANTECH FORM QTC2 eg1 515 60 Factory wired with optional transformer LD03611 Control Wiring...