QUANTECH
47
SECTION 5 – TECHNICAL DATA
Form QCC2-NM1
Issue Date: 5/20/2021
5
Electrical notes and legend
DESIGNATION
DESCRIPTION
ACC
Accessory
- ADIS
Display Board
- AMB
Micro Board
- BAMB
Ambient
- BDAT
Discharge Air Temperature
- BDP
Discharge Pressure
- BECT
Entring Chilled Temperature
- BLCT
Leaving Chilled Temperature
Not Fitted On Remote Evap Units
-BMP
Motor Protector Compressor
- BSP
Suction Pressure
- CPF
Capacitor Power Factor
- ECH
Crankcase Heater
- EEH
Evaporator Heater
- EHRH
Heat Recovery Heater
- EPH
Pump Heater
- EXT
External To Control Panel
- F
Fuse
- FHP
High Pressure Cutout
- FSC
Fan Speed Controller
- FSI
Fan Speed Inhibit Two Speed
Fan Option Only
GND
Ground
G/Y
Green / Yellow
J
Plug Board Connector
- K
Circuit Board Relay
- KF
Fan Contactor Line
(Including Coil Suppressor)
- KFH
Fan Contactor High Speed
(Including Coil Suppressor)
- KFL
Fan Contactor Low Speed
(Including Coil Suppressor)
- KFOL
Fan Overload
- KFS
Relay Fan Speed
- KH
Heater Relay
- KM
Compressor Contactor (Including Coil
Suppressor)
- KCR
Control Relay
- KP
Pump Contactor Part
(Including Coil Suppressor)
- KT
Relay Timer
- M
Compressor Motor
- MF
Motor Fan
DESIGNATION
DESCRIPTION
- MP
Motor Pump
NU
Not Used
PE
Protective Earth
PWM
Pulse Width Modulation Temp Reset
Or Remote Unload 2Nd Step
- QCB
Circuit Breaker
- QMMSC
Manual Motor Starter
Compressor
- QMMSP
Manual Motor Starter Pump
- QSD
Switch Disconnect
R
Resistor
RED
Red
RP
Run Permissive
RU
Remote Unload 1St Step
SCH
Thermostat Crankcase Heater
SCR
Screen
- SF
Flow Switch
- SKP
Keypad
- SOA
Switch Off Auto
- SZT
Zone Thermostat
- T
Transformer
- TC
Transformer Current
- UBR
Brigde Recfifier
- WHT
White
- XP
Plugs Between Pow./Microboard.
Section
- XTBC
Terminal Block Customer
- XTBF
Terminal Block Factory
- YESV
Evaporator Solenoid Valve
- YHGSV
Hot Gas Solenoid Valve (Including Coil
Suppressor)
- YLLSV
Liquid Line Solenoid Valve Field
Mounted And Wired On Remote Evap.
Units
- ZCPR
Compressor
NB
Note Well
{See Note}
Wiring And Items Shown Thus Are
Standard York Accessories
Wiring And Items Shown Thus Are Not
Supplied By York
Items Thus Enclosed Form A
Components Or Sets Of Components
035-21966-101 REVG
Summary of Contents for QCC2015CEE
Page 12: ...QUANTECH 12 Form QCC2 NM1 Issue Date 5 20 2021 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 38: ...QUANTECH 38 Form QCC2 NM1 Issue Date 5 20 2021 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 102: ...QUANTECH 102 Form QCC2 NM1 Issue Date 5 20 2021 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 152: ...QUANTECH 152 Form QCC2 NM1 Issue Date 5 20 2021 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 171: ...QUANTECH 171 Form QCC2 NM1 Issue Date 5 20 2021 Notes...