Settings page
71
Alarms settings panel
Alarms are the result of one or more error conditions. Four alarms are
available, numbered 1-4, and each may have any combination of errors
assigned to it. When an error occurs, it triggers any alarms to which it
is assigned. Triggering an alarm results in actions based on settings in
the Alarm Actions settings panel (p. 72).
The Alarms settings panel has a column for each of the four alarms. It
has a row for each type of detected error. Within each column, checked
boxes indicate the errors assigned to the alarm.
Signal Errors
Under Level
Enables reporting of under-level errors.
Over Level
Enables reporting of levels exceeding the specified operat-
ing level.
Clipping
Enables reporting of channel clipping.
Hum
Enables reporting mains hum errors.
Program Loudness
Enables reporting of short-term loudness exceeding
the maximum allowed.
Integrated Loudness
Enables reporting of integrated loudness being
outside the allowable tolerances.
Downmix Compatibility
Enables reporting of stereo and mono downmix
compatibility errors.
Channel Swap
Enables reporting of interchanged channels.
LFE Bandwidth
Enables reporting of excessive LFE bandwidth.
Digital Interface Errors
Input Connections
Enables reporting of digital input link errors.
Group Consistency
Enables reporting of cross channel format inconsis-
tencies.
Input Metadata
Enables reporting of individual channel metadata errors.
Group Metadata
Enables reporting of cross channel metadata inconsis-
tencies.
Coded Audio Errors
Enables reporting of packet coding errors.
Coded Audio Metadata
Enables reporting of errors in the coded audio
metadata
Summary of Contents for Sentine
Page 1: ...Sentinel surround sound audio monitor User Manual Version 2 0 May 2011...
Page 2: ......
Page 3: ...User Manual Version 2 0 May 2011 Qualis Audio Inc Lake Oswego Oregon...
Page 7: ...1 1 Overview...
Page 10: ...4...
Page 23: ...17 3 Front Panel Front panel displays and controls 18 Front Panel menus 19...
Page 28: ...22...
Page 80: ...74...
Page 88: ...82...
Page 94: ...88...
Page 95: ...89 8 Firmware updates...
Page 102: ...96...
Page 104: ...98...
Page 107: ......
Page 108: ...We re Listening Qualis Audio Inc Lake Oswego Oregon...