70
User Manual
DC Inputs & Temperature settings panel
The DC Inputs & Temperature settings panel sets the limit thresholds
for the 6 DC inputs and the internal temperature sensor. These have
no duration setting – if a threshold is crossed, an error is immediately
asserted.
Report An Error if
DC In # Is Above
Sets the maximum DC value allowed on that input
before issuing an error. The value may be set between 0.30V
and 2.55V in 0.15V steps. Set this to 2.55V to disable this com-
parison.
Or Below
Sets the minimum DC value allowed on that input before issu-
ing an error. The value may be set between 0.0V and 2.25V in
0.15V steps. Set this to 0.0V to disable this comparison.
Temperature Is Above
Sets the maximum temperature allowed before
issuing an error. The value may be set between 32° C and 62°
C in 2° steps.
Or Below
Sets the minimum temperature allowed before issuing an error.
The value may be set between 4° C and 19° C in 1° steps.
See Auxiliary signals connection (p. 14) for details about connecting
these inputs.
Error reporting for each auxiliary input is enabled in the Alarms settings
panel (p. 71).
Summary of Contents for Sentine
Page 1: ...Sentinel surround sound audio monitor User Manual Version 2 0 May 2011...
Page 2: ......
Page 3: ...User Manual Version 2 0 May 2011 Qualis Audio Inc Lake Oswego Oregon...
Page 7: ...1 1 Overview...
Page 10: ...4...
Page 23: ...17 3 Front Panel Front panel displays and controls 18 Front Panel menus 19...
Page 28: ...22...
Page 80: ...74...
Page 88: ...82...
Page 94: ...88...
Page 95: ...89 8 Firmware updates...
Page 102: ...96...
Page 104: ...98...
Page 107: ......
Page 108: ...We re Listening Qualis Audio Inc Lake Oswego Oregon...