background image

2

January 8, 2019

7082-154E

TREKKER INSERT

Mt Vernon E2-C / Trekker

Pellet Insert

R

Listed Solid Fuel Room Heater/Pellet Type.  Also suitable for Mobile Home Installation.  This appliance has 

been tested and listed for use in Manufactured Homes in accordance with OAR 814-23-9000 through 

814-23-909.

Appareil de chauffage de combustible solide/de type de boulettes.  Accepté dans l'installation dans les 

maisons mobiles.  Cet appareil a été testé et enregistré pour l'usage dans les Maisons Mobiles en accord 

avec OAR 814-23-9000 jusqu'à 814-23-909.

PREVENT HOUSE FIRES / 

PRÉVENTION DES FEUX DE MAISON

Install and use only in accordance with manufacturer's installation and operating instructions.  Contact local 

building or fire officials about restrictions and inspection in your area.

WARNING - FOR MOBILE HOMES:  Do not install appliance in a sleeping room.  An outside combustion air 

inlet must be provided.  The structural integrity of the mobile home floor, ceiling and walls must be maintained.  

Refer to manufacturer's instructions and local codes for precautions required for passing chimney through a 

combustible wall or ceiling.  Inspect and clean vent system frequently in accordance with manufacturer's 

instructions.  DO NOT CONNECT THIS UNIT TO A CHIMNEY SERVING ANOTHER APPLIANCE.  Use a 3" 

or 4" diameter type "L" or "PL" venting system.

Installez et utilisez en accord avec les instructions d'installation et d'opération du fabricant. Contactez le 

bureau de la construction ou le bureau des incendies au sujet des restrictions et des inspections d'installation 

dans votre voisinage. Ne pas obstruez l'espace en dessous de l'appareil.

AVIS - Pour Les Maisons Mobiles:  Ne pas installer dans une chambre à coucher. Un tuyau extérieur de 

combustion d'air doit être installé et ne doit pas être obstrué lorsque l'appareil est en usage. La structure 

intégrale du plancher, du plafond et des murs de la maison mobile doit être maintenue intacte.  Référez vous 

aux instructions du fabricant et des codes locaux pour les précautions requises pour passer une cheminée à 

travers un mur ou un plafond combustibles, et les compensations maximums.  Inspectez et nettoyez la 

cheminée fréquemment. Ne pas connecter cet appareil à une cheminée servant un autre appareil.  Utilisez 

systèm de ventilation "L" ou "PL" diamètre 76mm ou 102mm

Conforms to ASTM Std E1509-12. Certified to ULC S628-93. Room Heating Pellet BurningType,  (UM) 

84-HUD FOR USE ONLY WITH PELLETIZED WOOD  FUEL. Do not use any other type of fuel.  
Input Rating: 50,775 Btu's/hr.  Electrical Rating:115 VAC, 60 Hz, Start 2.9 Amps, Run 2.45 Amps.  Route 

power cord away from unit.  Do not route cord under or in front of appliance.  Do not obstruct the space 

beneath the heater.

DANGER

:  Risk of electrical shock.  Disconnect power supply before servicing.  Replace glass only with 5mm 

ceramic.  To start, turn dial control to desired setting and set thermostat above room temperature, the stove 

will light automatically.  To shutdown, turn dial control to OFF or set thermostat below room temperature.  For 

further instruction refer to owner's manual.  Keep viewing doors tightly closed during operation.  Keep viewing 

and ash removal doors tightly closed during operation.
Conforme à la norme ASTM E1509-12 Std. Certifié à la norme ULC S628-93. Room Heating Pellet Burning 

Type, (UM) 84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS.  N’utiliser aucun autre genre de 

combustible.  
Puissance de Rendement: 50,775 Btu's/hr.  

Puissance Électrique: 115 VAC, 60 Hz,

 Début 2.9 Amps, Courir 

2.45 Amps, Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en 

dessous 

de l'appareil.  

Ne pas bloquer l’espace au dessous de l’appareil

.  

DANGER:

 Il y a risque de décharge électrique.  Déconnectez le fil électrique de la prise de contact avant le 

service.  Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur.  

Pour commencer, tournez la molette de réglage à la température désirée et réglez le thermostat au-dessus de 

la température ambiante, le poêle s'allumera automatiquement. Pour éteindre, tournez la molette de réglage 

sur OFF ou réglez le thermostat dessous de la température ambiante.  Pour des instructions supplémentaires, 

référez vous au manuel du propriétaire.  Gardez la porte d'ouverture et la porte des cendres fermées 

hermétiquement durant l'opération.

7082-152D

HOT WHILE IN OPERATION DO NOT TOUCH, KEEP 

CHILDREN, CLOTHING AND FURNITURE AWAY. 

CONTACT MAY CAUSE SKIN BURNS.  SEE NAMEPLATE AND INSTRUCTIONS.  

CAUTION:

CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. 

GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE 

L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES 

BRÛLURES À LA PEAU.  VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS.  

ATTENTION:

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS / ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES
AS A BUILT-IN UNIT / COMME APPAREIL INSÉRÉ

A  Top of Hopper / Haut de la trémie 

Top/Rear Vent / Des Conduits Du Haut/Arrières 

3 in [76mm]

B  Side of Outside Skin / Côté de Enveloppe extérieure 

Top/Rear Vent / Des Conduits Du Haut/Arrières 

2 in [51mm]

C   Vent Pipe to Combustible / Des Conduits de combustible 

Top/Rear Vent / Des Conduits Du Haut/Arrières 

3 in [76mm]

D  Cast Side to Side Wall / Moulage Side à Wall Side 

Top/Rear Vent / Des Conduits Du Haut/Arrières 

6 in [152mm]

D

B

B

C

A

MASONRY OR ZERO CLEARANCE / DÉGAGEMENT DE LA MAÇONNERIE OU DÉGAGEMENT ZÉRO*

SIDE W

ALL

 / MUR LA

TÉRAL

MANTEL / MANTEAU

C

A

B

D

E

A Cast Side to Side Wall / Moulage Side à Wall Side 

6 in [152 mm]

B Insert top to face trim / Insérez le dessus de la garniture de façade 

0 in [0 mm]

C Insert side to face trim / Insérez le côté de la garniture de façade 

0 in [0 mm]

D Hearth extension from door opening / Prolongement d’âtre depuis l’ouverture de la porte devant 

6 in [152 mm]

E Hearth extension from side of door opening / Prolongement d’âtre depuis le côté de l’ouverture de la porte 

6 in [152 mm]

U.S. ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with 2020 particulate standards at 0.74 G/HR. 

Tested under ASTM E2515, ASTM E2779, and CSA B415.1-10

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE

Made in U.S.A. 

of US and imported parts.

Fabriqué aux États-Unis-d’Amérique par des pièces d’origine américaine et pièces importées.

2018

2019

2020

JAN

FEB

MAR

APR

MAY

JUN

JUL

AUG

SEP

OCT

NOV

DEC

352 Mountain House Road, Halifax, PA 17032

www.quadrafire.com

Manufactured by:Fabriqué par

Safety and Emissions 

Respectively

Report #: 061-S-84-2

Report #: 0061Ps094E 

Serial No. / N° de série

HF

BARCODE LABEL

This wood heater needs periodic inspection and repair for 

proper operation. Consult the owner’s manual for further 

information. It is against federal regulations to operate this 

wood heater in a manner inconsistent with the operating 

instructions in the owner’s manual.

MTVI-E2-C

TREKKER-I

A. Sample of Serial Number / Safety Label

LOCATION: Behind right cast side panel

Serial No.

Model Name

Test Lab & 

Report No.

Mfg. Date

SAMPLE

and Welcome to the Quadra-Fire Family

!

NOTE:

 Clearances may only be reduced by means approved 

by the regulatory authority having jurisdiction

Summary of Contents for TREKKER INSERT series

Page 1: ...ation in these instructions is not followed exactly a fire could result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicin...

Page 2: ...ent 50 775 Btu s hr Puissance lectrique 115 VAC 60 Hz D but 2 9 Amps Courir 2 45 Amps loignez le fil lectrique de l appareil Ne pas faire passer le fil lectrique au dessus ou en dessous de l appareil...

Page 3: ...ntenance and Service 14 A Proper Shutdown Procedure 14 B Quick Reference Maintenance Chart 14 C General Maintenance and Cleaning 15 D Soot or Creosote Fire Awareness 18 E High Ash Fuel Content Mainten...

Page 4: ...ronic components and glass X X X Factory installed blowers X Molded refractory panels X Ignition Modules X Firepots burnpots mechanical feeders auger assemblies X Vent Free burners Vent Free ceramic f...

Page 5: ...nging a warranty call Travel and shipping charges for parts are not covered by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warranted...

Page 6: ...o water or weather damage which is the result of but not limited LIMITATIONS OF LIABILITY have other rights which vary from state to state EXCEPT TO THE EXTENT PROVIDED BY LAW HHT MAKES NO EXPRESS WAR...

Page 7: ...Plug in the ap pliance exhaust blower will run for about 45 seconds wait for it to stop before moving to manual feed 65 72 HEATING 5 From the OFF home screen press and hold the outer ring for 3 second...

Page 8: ...ood Pellets Weighted average LHV efficiency using data collected during EPA emissions test Weighted average HHV efficiency using data collected during EPA emissions test A range of BTU outputs based o...

Page 9: ...gov G California Prop65 F Sleeping Room When installed in a sleeping room it is recommended that 3ft of vertical be installed prior to horizontally exiting the room and a smoke CO alarm be installed...

Page 10: ...content That is why some fuels produce more clinkers than others Moisture Always burn dry fuel Burning fuel with high moisture content takes heat from the fuel and tends to cool the appliance robbing...

Page 11: ...opened This startup cycle continues until the unit senses ignition by a rise in the exhaust temperature or the unit times out Following the ignition cycle the unit continues to feed pellets to build u...

Page 12: ...adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away Figure 12 2 8 30 AM TUNIN...

Page 13: ...llers becoming dirty over time See maintenance and service section for maintaining and servicing What is the metal object with the bend in it that came inside the plastic bag It is a clean out tool us...

Page 14: ...e for your appliance Visit www quadrafire com owner resources to view basic troubleshooting FAQs use care videos We recommend annual service by a qualified dealer Cleaning or Inspection Frequency Dail...

Page 15: ...sh pan will have to be cleaned out more often than ash Ash Disposal Ashes should be placed in a steel container with a tight fitting lid The container of ashes should be moved outdoors immediately and...

Page 16: ...he heat exchanger fins It is critical that the 2 exhaust exits at the back of the firebox floor left and right be thoroughly cleaned Figure 16 2 There are several ways this can be done Use the crevice...

Page 17: ...d This can result in nuisance shut downs and mis starts Empty the hopper of any remaining pellets Vacuum the hopper and feed tube Figure 17 1 Ash Dump Lever WARNING Risk of fire Do NOT store fuel Clos...

Page 18: ...me soot formation which will collect in the exhaust venting system NOTE Ash will build up more quickly in the horizontal venting sections 13 Preparing Firebox for Non Burn Season Frequency See chart o...

Page 19: ...down The bottom of the latch will fall forward off of the post Lift the baffle up and then out toward you Figure 19 2 5 To replace the baffle place the 2 locating ears behind the bottom edge and tilt...

Page 20: ...remove the motor and impeller 4 Disconnect the wire from the control board connection and hall effect switch housing 5 Using an 7mm socket wrench or nut driver loosen the nuts securing the motor and...

Page 21: ...t functioning Check hopper switch operation Check hopper switch wires for integrity Check hopper lid on correctly Check hopper lid magnet is installed Safety snap disc is tripped not functioning Check...

Page 22: ...Secure the exhaust probe to exhaust blower housing keeping its wire away from hot surfaces Defective probe Replace probe Control board is defective Replace control board Convection Blower fails to shu...

Page 23: ...off Excessive fuel spilling over the fire pot and or excessive flame Dirty Appliance Clean unit including the fire pot exhaust path and venting system Feed Motor locked on Follow corrective action for...

Page 24: ...niter lead connections or replace igniter Exhaust probe not properly installed Secure exhaust probe to exhaust blower housing keeping its wire away from hot surfaces Igniter chamber plugged with debri...

Page 25: ...through the venting system 2 Control Board The control board is located on the right side of appliance It controls the functioning of the appliance and communicates with the user interface through the...

Page 26: ...26 January 8 2019 7082 154E TREKKER INSERT B Service and Maintenance Log Date of Service Performed By Description of Service...

Page 27: ...27 January 8 2019 7082 154E TREKKER INSERT Date of Service Performed By Description of Service...

Page 28: ...KKER INSERT Beginning Manufacturing Date June 2018 Ending Manufacturing Date Active Pellet Insert TREKKERI CSB TREKKERI MBK TREKKERI PMH Part number list on following pages 01 19 1 2 3 4 5 6 7 8 9 10...

Page 29: ...07CSB Gasket Extruded Field Cut to Size 10 FT 7000 320 10 2 Top Hinge Assembly SRV7036 006 3 Top Matte Black 7036 101MBK Porcelain Mahogany 7036 101PMH Sienna Bronze 7036 101CSB 4 Catch Clip 7036 146...

Page 30: ...Gasket Channel 3 Mm X 32 Field Cut to Size 10 Ft 7000 377 10 Y 17 Ash Pan Door SRV7034 133 18 Ash Pan Assembly SRV7034 069 Twin Ball catch SRV7000 532 Y 19 Intake Shield 7034 224 Y 20 Firepot Riser As...

Page 31: ...29 Combustion Blower SRV7080 106 Y Gasket Blower Combustion Between Housing Stove SRV7080 117 Y Gasket Motor Blower Combustion Between Housing Motor SRV7080 107 Y Gasket Exhaust SRV7034 109 30 Flue C...

Page 32: ...Flue Adapter Required if TPVNT 4 is removed LKADP Surround Std Panel For Cast Trim SP MTVS CST Component Pack 7036 041 Surround Std Panel w Gold Trim No longer available SP MTVS GD Component Pack 7036...

Page 33: ...Washer Sae Pkg of 25 227 0080 25 Y Washer FI 1 4 Black Pkg of 10 1202473 10 Pkg of 50 1202473PK Screw Hwh Ms 1 4 20 X 3 4 Ns Pkg of 25 220 0080 25 Y Nut Ser Flange Small 1 4 20 Pkg of 24 226 0130 24 Y...

Page 34: ...purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Deal...

Reviews: